User's Manual

Receiver Model : WH2802
Sensor Model : WH32G
Version 1.0 Page 14
Command
Function
Description
Settings
SET and
BARO/- + 5
seconds
OUTDOOR
TEMP
Calibrate the outdoor
temperature
Press TEMP/+ or BARO/- to
increase or decrease the outdoor
temperature offset.
SET
OUTDOOR
HUMIDITY
Calibrate the outdoor
humidity
Press TEMP/+ or BARO/- to
increase or decrease the outdoor
humidity offset.
SET
INDOOR
TEMP
Calibrate the indoor
temperature
Press TEMP/+ or BARO/- to
increase or decrease the indoor
temperature offset.
SET
INDOOR
HUMIDITY
Calibrate the outdoor
humidity
Press TEMP/+ or BARO/- to
increase or decrease the indoor
humidity offset.
SET
PRESSURE
Calibrate the relative
pressure
Press TEMP/+ or BARO/- to
increase or decrease relative pressure
offset.
SET
Exit Set Mode
Figure 12
Example 1:
The calibrated temperature from a red spirit thermometer, or actual temperature is 60.0 °F.
The uncalibrated or measured temperature is 58.7 °F.
Offset = Calibrated Temperature Uncalibrated Temperature = 60.0 58.7 = 1.3 °F.
Enter the temperature offset +1.3 °F.
Example 2:
The calibrated relative pressure at the local airport is 29.86 inHg.
The uncalibrated or measured relative pressure measured by the weather station is 29.92 inHg.
Offset = 29.86 29.92 = -0.06 inHg
Enter the relative pressure offset -0.06 inHg
To exit the calibration mode at any time, press the LIGHT/SNOOZE button.
Note: The calibration offset range limits are as follows:
Temperature: ± 9°F
Humidity: ± 9%
Relative: ± 10hpa (± 0.295 inHg)
4.6 Max/Min Mode
The Max/Min data is displayed below each parameter. The orange parameter on the left is the
maximum value since the last reset, and the blue parameter on the left is the minimum value since
the last reset.