User's Manual
- 11 -
- Press the HISTORY key or key idle 10 second, the Min/Max mode will return to Normal Mode
6. Problems and interference with operation
Problem & cause Remedy
Distance between transmitters and
receiver too long
Reduce distance between transmitters and receiver to receive
signal
High shielding materials between the units
(thick walls, steel, concrete, isolating
aluminum foil and etc.)
Find a different location for sensors and/or receiver. See also
item ‘transmission range’ below
Interference from other sources (e.g.
wireless radio, headset, speaker, etc.
operating on the same frequency)
Find a different location for the sensors and/or base station.
Neighbors using electrical devices operation on the same
signal frequency can also cause interference with reception
No reception after adding extension
cables
Find a new location for the sensors and/or base station.
Poor contrast LCD or no reception or low
batteries in sensors or receiver
Change batteries
Temperature, humidity, or air pressure is
incorrect.
Check/replace batteries. If multiple remote sensors are in use,
check location with corresponding “boxed numbers”. Or move
away from sources of heat/cold. Adjust relative air pressure to
a value from a reliable source (TV radio, etc.).
7. Specifications
Outdoor data
Transmission distance in open field : 100meter max.
Frequency : 433MHz
Temperature range : -30℃ to +65℃ (show OFL if outside range)
Resolution : 0.1℃
Measuring range rel. humidity : 10%~99%
Rain volume display : 0 - 9999mm (show OFL if outside range)
Resolution : 0.3mm (if rain volume < 1000mm)
1mm (if rain volume > 1000mm)
Wind speed : 0~180km/h (show OFL if outside range)
Measuring interval thermo-hygro sensor : 48 sec
Water proof level : IPX3
Indoor data
Pressure / temperature : 48 sec
Indoor temperature measure range : 0℃ to +60℃ (reading range: -20℃ to +65℃)
Resolution : 0.1℃
Measuring range rel. humidity : 10%~99%
Resolution : 1%
Measuring range air pressure : 300-1100hPa (8.85-32.5inHg)
Accuracy : +/-3hpa under 700-1100hPa
Resolution : 0.1hPa (0.01inHg)
Alarm duration : 120 sec
Power consumption
Base station : 3XAA 1.5V LR6 Alkaline batteries
Remote sensor : 2xAA 1.5V LR6 Alkaline batteries
Battery life : Minimum 12 months for base station
Minimum 24 months for thermo-hygro sensor