User Manual
- 28 -
Problem Solution
Put batteries back in and resync with console by powering down and
up the console with the sensor array about 10 feet away.
Bring the sensor array inside the house (you can disconnect it from
the rest of the sensors). The LED next to the battery compartment will
flash every 16 seconds. If the LED is not flashing every 16
seconds…
Replace the batteries in the outside sensor array. Non-rechargeable
batteries are OK for testing purposes.
If the batteries were recently replaced, check the polarity. If the sensor
is flashing every 48 seconds, proceed to the next step.
There may be a temporary loss of communication due to reception
loss related to interference or other location factors,
or the batteries may have been changed in the sensor array and the
console has not been reset. The solution may be as simple as
powering down and up the console.
Replace the batteries in the outside sensor array. Non-rechargeable
batteries are OK for testing purposes.
With the sensor array and console 10 feet away from each other,
remove AC power from the display console and wait 10 seconds.
Re-connect power.
Temperature sensor
reads too high in the
day time.
Make certain that the sensor array is not too close to heat generating
sources or strictures, such as buildings, pavement, walls or air
conditioning units.
Use the calibration feature to offset installation issues related to
radiant heat sources. Reference 4.3.
Absolute pressure
does not agree with
official reporting
station
You may be viewing the relative pressure, not the absolute pressure.
Select the absolute pressure. Make sure you properly calibrate the
sensor to an official local weather station. Reference Section 4.3 for
details.
Rain gauge reports
rain when it is not
raining
An unstable mounting solution (sway in the mounting pole) may result
in the tipping bucket incorrectly incrementing rainfall. Make sure you
have a stable, level mounting solution.
Data not reporting to
Wunderground.com
1. Confirm your password is correct. It is the password you
registered on Wunderground.com. Your Wunderground.com
password cannot begin with a non-alphanumeric character (a
limitation of Wundeground.com, not the station). Example,
$oewkrf is not a valid password, but oewkrf$ is valid.
2. Confirm your station ID is correct. The station ID is all caps, and
the most common issue is substituting an O for a 0 (or visa
versa). Example, KAZPHOEN11, not KAZPH0EN11
3. Make sure the date and time is correct on the console. If
incorrect, you may be reporting old data, not real time data.
4. Make sure your time zone is set properly. If incorrect, you may be
reporting old data, not real time data.
5. Check your router firewall settings. The console sends data via