Down arrow key
Press this key to change the activated option field
Set key
Press this key to select the Setting sub-Mode
Return key
Press this key to return to previous mode
To adjust the parameter, press to scroll to the parameter you wish to change. Press to highlight the
sign (positive vs. negative, if applicable) and significant digit. Press
or to change the calibrated
value.
Parameter Type of
Calibration
Default Typical Calibration Source
Temperature Offset Current Value Red Spirit or Mercury
Thermometer (1)
Humidity Offset Current Value Sling Psychrometer (2)
ABS
Barometer
Offset Current Value Calibrated laboratory grade
barometer
REL
Barometer
Offset Current Value Local airport (3)
Wind
Direction
Offset Current Value GPS, Compass (4)
Solar
Radiation
Gain 1.00 Calibrated laboratory grade
solar radiation sensor
1 w/m
2
Gain 126.7 lux Solar radiation conversion
from lux to w/m
2
for
wavelength correction (5)
Wind Gain 1.00 Calibrated laboratory grade
wind meter (6)
Rain Gain 1.00 Sight glass rain gauge with
an aperture of at least 4” (7)
Daily Rain Offset Current Value Apply an offset if the
weather station was not
operating for the entire day.
Weekly Rain Offset Current Value Apply an offset if the
weather station was not
operating for the entire
week.
Monthly Rain Offset Current Value Apply an offset if the
weather station was not
operating for the entire
month.
Yearly Rain Offset Current Value Apply an offset if the
weather station was not
operating for the entire year.
(1) Temperature errors can occur when a sensor is placed too close to a heat source (such as a building
structure, the ground or trees).
To calibrate temperature, we recommend a mercury or red spirit (fluid) thermometer. Bi-metal (dial) and
digital thermometers (from other weather stations) are not a good source and have their own margin of
error. Using a local weather station in your area is also a poor source due to changes in location, timing
(airport weather stations are only updated once per hour) and possible calibration errors (many official
weather stations are not properly installed and calibrated).
Place the sensor in a shaded, controlled environment next to the fluid thermometer, and allow the
sensor to stabilize for 48 hours. Compare this temperature to the fluid thermometer and adjust the
console to match the fluid thermometer.