Datasheet

97.01
97.02
97.02
97.01
3.5 23 19.2 19.2
64.6
25.935.421.6
31.8
49.9
97.02 + 46.52 + 097.01
+ 86.30
11
97.01
Approvals
(according to type):
86 Series - Sockets and accessories
Screw terminal socket 97.01 97.02
panel or 35 mm rail (EN 60715) mount Blue Blue
For relay type 46.61 46.52
Accessories
Plastic retain and eject clip 097.01
(supplied with socket - packaging code SPA)
8-way jumper link 095.18 (blue) 095.18.0 (black)
Identification tag 095.00.4
Timer modules 86.30
Technical data
Rated current
16 A - 250 V AC 8 A - 250 V AC
Dielectric strength 6 kV (1.2/50 µs) between coil and contacts
Protection category IP 20
Ambient temperature °C –40…+70 (see diagram L97)
Screw torque Nm 0.8
Wire strip length mm 8
Max. wire size for 97.01 and 97.02 sockets solid wire stranded wire
mm
2
1x6 / 2x2.5 1x4 / 2x2.5
AWG 1x10 / 2x14 1x12 / 2x14
8-way jumper link for 97.01 and 97.02 sockets 095.18 (blue) 095.18.0 (black)
Rated values 10 A - 250 V
Rated current (A)
L 97 - Rated current vs ambient temperature
(for 46.61 relay / 97.01 socket combination)
095.18
097.01
E
U
R
O
P
E
A
N
E
U
R
O
P
E
A
N
PATENT
II-2014, www.findernet.com
86
SERIES
Timers and Monitoring relays