Surge Protection Device (SPD) 7P SЕRIES Panels for electrical distribution Control panels Surge protection Road / tunnel lighting Elevators and lifts
FINDER reserves the right to alter characteristics at any time without notice. FINDER assumes no liability for damage to persons or property, caused as a result of the incorrect use or application of its products.
7P SERIES Surge Protection Device (SPD) XI-2017, www.findernet.
E 7P SERIES Surge Protection Device (SPD) SPD Type 1+2 Surge arrester range - three phase high discharge capability with no following current - system (230/400 V) • Surge arresters, suitable for low-voltage applications, to protect equipment against overvoltage by direct lightning strike, induced overvoltage and switching overvoltage • To be installed at the boundary of LPZ 0 - LPZ 1 zones or higher • Combined high energy varistor block and high-performance spark gap (GDT) ensures: --high discarge curr
7P SERIES Surge Protection Device (SPD) SPD Type 1+2 Surge arrester range with high performance “Low Up” - Single phase/three phase system • Surge arrester suitable for 230/400 V system applications to prevent overvoltage effects caused by direct or indirect lightning strikes • To be installed at the boundary of LPZ 0 and LPZ 1 zones • Very Low Up level to protect senstive equipment • Visual indication of varistor status Healthy/Replace • Contact for remote signalling of varistor status. Connector 07P.
7P SERIES 7P SERIES Surge Protection Device (SPD) SPD Type 1+2 Surge arrester range with high performance “Low Up” - three phase system 7P.14.8.275.1012 7P.15.8.275.
XI-2017, www.findernet.com 7P SERIES Surge Protection Device (SPD) 7P SERIES SPD Type 2 Surge arrester range for single/ 7P.21.8.xxx.x0xx 7P.22.8.275.x020 7P.27.8.275.
7P SERIES 7P SERIES Surge Protection Device (SPD) SPD Type 2 Surge arrester range - three phase systems 7P.23.8.275.x020 7P.24.8.275.x020 7P.25.8.275.x020 • Surge arrester suitable for 230/400 V system applications to protect equipments against induced overvoltage or switching transients • To be installed at the boundary of LPZ 1 - LPZ 2 zones or higher • Visual indication of varistor status Healthy/Replace • Contact for remote signalling of varistor status. Connector (07P.
7P SERIES Surge Protection Device (SPD) SPD Type 2 Surge arrester range for Photovoltaic applications 7P SERIES 7P.26.9.420.1020 7P.23.9.750.x020 7P.23.9.500.1015 • Surge arrester for protection of DC side (420 V to 1200 V) of systems in photovoltaic applications • Protects equipment against induced overvoltage caused by lightning strikes or switching transients 7P.26.9.420.1020, UCPV = 420 V DC 7P.23.9.750.x020, UCPV = 750 V DC 7P.23.9.500.
7P SERIES 7P SERIES Surge Protection Device (SPD) 7P.26.9.000.x015 7P.23.9.000.x015 7P.03.9.000.1012 • Visual indication of varistor status - • SPD Type 2 (2 varistors + 1 • SPD Type 2 (3 varistors) for • SPD Type 1+2 (3 varistors) Healthy/Replace • Contact for remote signalling of varistor status. Connector (07P.
7P SERIES Surge Protection Device (SPD) SPD Type 3, Surge arrester for TT and TN-S system (with Neutral) Single phase applications within socket outlets and 35 mm rail mounting 7P SERIES 7P.31.8.275.0005 7P.32.8.275.0005 • Protects electrical and electronic equipment sensitive to impulse overvoltage • Varistor and spark gap (GDT) combination avoiding earth leakage current • Conforms to EN 61643-11:2012 7P.31.8.275.
7P SERIES Surge Protection Device (SPD) 7P.37.8.275.1003 P 7P.36.8.275.
7P SERIES Surge Protection Device (SPD) 7P SERIES 7P.62.9.009.0485 SPD Type 2+3 with combination of coarse and fine suppression for 2 wires telecomunication and signalling network 7P.62.9.036.
7P SERIES 7P SERIES Surge Protection Device (SPD) 7P.68.9.060.0600 Data line SPD for Ethernet Cat.
7P SERIES Surge Protection Device (SPD) 7P SERIES Ordering information Example: 7P series, surge protection device, Type 2, single phase (UC = 275 V), 1 varistor + 1 encapsulated spark gap, with remote status signalling contact, In = 20 kA 7 P . 2 2 . 8 . 2 7 5 . 1 0 2 0 Nominal discharge current 100 = 1 00 kA (Iimp Type 1) only for 7P.09, N-PE GDT for 7P.04 050 = 5 0 kA (Iimp Type 1 N-PE GDT for 7P.
7P SERIES 7P SERIES Surge Protection Device (SPD) Replaceable modules Maximum operating voltage (UC/UCPV ) V AC/DC 7P.00.8.260.0025 7P.00.9.500.0012 7P.00.1.000.0050 7P.00.1.000.0100 Varistor Varistor Spark-Gap Spark-Gap 260/— —/500 255/— 255/— Lightning Impulse current (10/350 μs) (Iimp) kA 25 12.5 50 100 Nominal discharge current (8/20 μs) (In) kA 30 30 50 100 Maximum discharge current (8/20 μs) (Imax) kA 60 60 100 100 Voltage protection level (Up) kV 1.5 1.
7P SERIES Surge Protection Device (SPD) - Dimensional data 7P SERIES Outline drawings Type 7P.09 Screw terminal Type 7P.01 Screw terminal Type 7P.02 Screw terminal PE PE E Type 7P.03 Screw terminal XI-2017, www.findernet.com Type 7P.
7P SERIES 7P SERIES Surge Protection Device (SPD) - Dimensional data Outline drawings Type 7P.05 Screw terminal Type 7P.12 Screw terminal Type 7P.13 Screw terminal Type 7P.14 Screw terminal Type 7P.15 Screw terminal Type 7P.21 Screw terminal Type 7P.22 / 7P.27 Screw terminal XI-2017, www.findernet.
7P SERIES Surge Protection Device (SPD) - Dimensional data 7P SERIES Outline drawings Type 7P.23.8 Screw terminal Type 7P.24 Screw terminal Type 7P.23.9 Screw terminal Type 7P.25 Screw terminal E Type 7P.26.9.420.1020 Screw terminal Type 7P.23.9.000.6020 Screw terminal Type 7P.37.8.275.1003 Screw terminal XI-2017, www.findernet.com Type 7P.26.9.000.
7P SERIES 7P SERIES Surge Protection Device (SPD) - Dimensional data Outline drawings Type 7P.68.9.060.0600 Type 7P.62.9.036.0005/7P.62.9.009.0485 Screw terminal E Type 7P.36.8.275.2003 Type 7P.31.8.275.0005/7P.32.8.275.0005 13 180 44 39 Type 7P.10/20 Replaceable module 07P.01 Connector XI-2017, www.findernet.com Type 7P.
7P SERIES Surge Protection Device (SPD) 7P SERIES Installation example - SPD Type 1 + 2 TT-SINGLE PHASE SYSTEM - SPD UP-STREAM OF RCD E Wiring diagrams “V-shape” (fuse max = 125 A) XI-2017, www.findernet.
7P SERIES 7P SERIES Surge Protection Device (SPD) Installation example for SPD Type 1 + 2 and Type 2 - Single phase TT-SINGLE PHASE SYSTEM - SPD UP-STREAM OF RCD TT or TN-S SINGLE PHASE SYSTEM - SPD DOWN-STREAM OF RCD Mandatory with LPS E Installation example for SPD Type 3 TN-S SINGLE PHASE SYSTEM - SPD DOWN-STREAM OF RCD TT or TN-S SINGLE PHASE SYSTEM - INCORPORATED IN SOCKET OUTLET N/L 7P.36.8.275.2003 XI-2017, www.findernet.
7P SERIES Surge Protection Device (SPD) 7P SERIES Installation example for SPD Type 1 + 2 and Type 2 - Three phase TT-THREE PHASE SYSTEM - SPD UP-STREAM OF RCD TT or TN-S THREE PHASE SYSTEM - SPD DOWN-STREAM OF RCD E Mandatory with LPS Note: suggested RCD type S TN-C THREE PHASE SYSTEM - SPD UP-STREAM OF OVERCURRENT PROTECTION XI-2017, www.findernet.
7P SERIES 7P SERIES Surge Protection Device (SPD) Installation example for SPD Type 3 - Single phase TT or TN-S SINGLE PHASE SYSTEM - SPD DOWN-STREAM OF RCD Serial connection TT or TN-S SINGLE PHASE SYSTEM - SPD DOWN-STREAM OF RCD Serial connection + BUS line Load PE Load PLC, Bus system, Remote monitoring L Input N PE Load PE 17.5 mm 12-24V DC E L1 Output N1 Load TT, TN-S SINGLE PHASE: parallel connection Function XI-2017, www.findernet.
7P SERIES Surge Protection Device (SPD) 7P SERIES L7P Temperature/Current diagram for model 7P.37 Zone I: SPD and other devices installed as a group (without gap) E Zone II: SPD spaced, at least from one side, from components that generate heat during their operation (17.5 mm gap) Zone III: SPD spaced, on both side, from components that generate heat during their operation (20 mm gap) XI-2017, www.findernet.
7P SERIES 7P SERIES Surge Protection Device (SPD) Installation examples - photovoltaic XI-2017, www.findernet.
7P SERIES Surge Protection Device (SPD) 7P SERIES SURGE VOLTAGE PROTECTORS Surge voltage protectors (such as Finder’s Surge Protection Devices, SPD) are intended to be installed in electrical systems, to protect people and machines from surge voltages that can occur on the electrical supply line and which would otherwise have disastrous consequences.
7P SERIES 7P SERIES Surge Protection Device (SPD) Rated values and marking common to all SPD [UC] Maximum continuous operating voltage: Under this voltage the SPD is guaranteed to appear as an “open switch”. This voltage is normally at least equal to the nominal supply voltage (UN) +10%. For the Finder SPD, UC is specified as 275 V. [Up] Voltage protection level: This is the highest voltage level seen across the SPD during its intervention.
7P SERIES Surge Protection Device (SPD) Short-circuit protection for the SPD is provided by the overcurrent protective devices (fuses type gL/gG) recomended. If the overcurrent protective devices F1 (which are part of the installation) have a rating smaller than or equal to the maximum recommended rating for the overcurrent protective devices for the SPD, then F2 (back up fuse), can be omitted.
7P SERIES 7P SERIES Surge Protection Device (SPD) PROTECTING PHOTOVOLTAIC (PV) SYSTEMS AGAINST LIGHTNING Installation characteristics [UOCSTC] PV voltage: Open circuit voltage, measured under standardized test conditions, of the PV module, panel, array, or the DC side of the photovoltaic inverter. prEN 50539-12. [ISCSTC]: Short-circuit current: Short-circuit current, measured under standardized test conditions, of the PV module, panel, array, or photovoltaic inverter. prEN 50539-12.
7P SERIES Surge Protection Device (SPD) 7P SERIES SPD fuse protection Conforming to prEN 50539-11:2010, Finder SPDs are equipped with a thermal disconnector able to safely disconnect a worn or damaged varistor up to a value of short-circuit current equal to the short-circuit current withstand value (Iscpv), as specified in the technical data. Ensure that the PV short circuit current Isc < Iscpv. Ensure that the PV short circuit current Isc < Iscpv or increase the number of the strings.