Data Sheet

4
4C Series - Relay interface modules 8 - 10 - 16 A
Contact specification
F 4C - Electrical life (AC) v contact current
Types 4C.01/51
(*) Type 4C.01= 12 A, Type 4C.51= 10 A
When switching a resistive load (DC1) having voltage and current
values under the curve, an electrical life of 100·10
3
can be expected.
In the case of DC13 loads, the connection of a diode in parallel with
the load will permit a similar electrical life as for a DC1 load.
Note: the release time for the load will be increased.
H 4C - Maximum DC1 breaking capacity
DC breaking current (A)
DC voltage (V)
F 4C - Electrical life (AC) v contact current
Types 4C.02/52
Current limit 1 CO (SPDT) (*)
Current limit 2 CO (DPDT)
Nominal Coil Operating range Resistance
Rated coil
voltage code
consumption
U
N
U
min
U
max
R
I
at U
N
VVVΩ mA
12 9.012 8.8 13.2 300 40
24 9.024 17.5 26.4 1,200 20
125 9.125 91.2 138 32,000 3.9
DC coil data
Coil specifications
Nominal Coil Operating range Resistance
Rated coil
voltage code
consumption
U
N
U
min
U
max
R
I
at U
N
VVVΩ mA
12 8.012 9.6 13.2 80 90
24 8.024 19.2 26.4 320 45
110 8.110 88 121 6,900 9.4
120 8.120 96 132 9,000 8.4
230 8.230 184 253 28,000 5
AC coil data
1 - Max. permitted coil voltage.
2 - Min. pick-up voltage with coil at ambient temperature.
R 4C - DC coil operating range v ambient temperature
1 - Max. permitted coil voltage.
2 - Min. pick-up voltage with coil at ambient temperature.
R 4C - AC coil operating range v ambient temperature
Temperature limit for the single pole version under full 16 A contact current.
Single Pole Relay
Contact Current
limited to 12 A
Single Pole Relay
Contact Current
limited to 12 A
Cycles
Resistive load - cosϕ = 1
Inductive load - cosϕ = 0.4
Cycles
Resistive load - cosϕ = 1
Inductive load - cosϕ = 0.4
limit for 4C.51