Datasheet

55
46
55 Series - Miniature General Purpose Relays 7 -10 A
CONTACT SPECIFICATIONS
Breaking capacity for DC1 load.
1 = 2 - 3 CO type.
2 = 4 CO type.
A = Load applied to 1 contact
B = Load applied to 2 contacts in series
C = Load applied to 3 contacts in series
D = Load applied to 4 contacts in series
When switching a resistive load (DC1) having voltage and
current values under the curve the expected electrical life is
100·10
3
cycles.
In case of DC13 loads the connection of a diode in parallel with
the load will permit the same electrical life as for a DC1 load.
Note: the release time of load will be increase.
Electrical life vs AC1 load.
1 = 4 CO relay type (7 A).
2 = 2 - 3 CO relay type (10 A).
124
0
16
8
10
6
10
5
10
7
2
1
F 55
LOAD RATED CURRENT (A)
CYCLES
20 60
100 140 180 220
20
10
6
4
2
1
0.2
0.1
A
B
C
D
1
2
H 55
CONDUCTED DISTURBANCE IMMUNITY BURST (according to EN 61000-4-4) level 4 (4 kV)
SURGE (according to EN 61000-4-5) level 4 (4 kV)
IMMUNITY
INSULATION according to EN 61810-5 insulation rated voltage V 400 (2-3 pole) 250 (4 pole)
rated impulse withstand voltage kV 3.6 (2-3 pole) 2.5 (4 pole)
pollution degree 2
overvoltage category III
TECHNICAL DATA
INSULATION
OTHER DATA
BOUNCE TIME: NO/NC ms 1/4
VIBRATION RESISTANCE (10…55Hz): NO/NC g/g 6/6
POWER LOST TO THE ENVIRONMENT 2 CO 3 CO 4 CO
- without contact current
W 111
- with rated current
W 343
RECOMMENDED DISTANCE between RELAYS mounted on P.C.B.s mm
5
DC VOLTAGE (V)
DC BREAKING CURRENT (A)
ACCESSORIES
055.05
Adaptor with top mount flange (for 55.32/33/34)
0
55.05
44.4
37.5
15
3.6
44.4
34.33.5
1.7