65 SЕRIES Power relays 20 - 30 A Infrared and microwave ovens Industrial washing machines Burners, boilers and furnaces Jacuzzis and hot tubs Power generators Panels for electrical distribution Back-up generators Industrial motors
FINDER reserves the right to alter characteristics at any time without notice. FINDER assumes no liability for damage to persons or property, caused as a result of the incorrect use or application of its products.
65 SERIES Power relays 20 - 30 A 65 SERIES 65.31 20 A Power relays 1 NO + 1 NC (SPST-NO + SPST-NC) 65.61 Type 65.31 - Flange mount and Faston 250 connections Type 65.61 - PCB mount A • AC coils & DC coils • Cadmium Free option available • 20 A rated contacts • Faston 250 (6.3 x 0.8 mm) connection • Flange mount • 20 A rated contacts • PCB mount • Bifurcated terminals * With the AgSnO2 material the maximum peak current is 120 A - 5 ms on NO contact.
65 SERIES 65 SERIES Power relays 20 - 30 A 65.31-0300 30 A Power relays 1 NO (SPST-NO) 65.61-0300 Type 65.31-0300 - Flange mount and Faston 250 connections Type 65.61-0300 - PCB mount A • ≥ 3 mm contact gap • AC coils & DC coils • Cadmium Free option available • 30 A rated contacts • Faston 250 (6.3 x 0.8 mm) connection • Flange mount • 30 A rated contacts • PCB mount • Bifurcated terminals * Distance between contacts ≥ 3 mm (EN 60335-1).
65 SERIES Power relays 20 - 30 A 65 SERIES Ordering information Example: 65 series power relay, PCB with bifurcated terminals, 1 NO + 1 NC (SPST-NO + SPST-NC) contact, 12 V DC coil. 6 5 . 6 A B C D 1 . 9 . 0 1 2 . 0 0 0 0 Series A: Contact material 0 = Standard AgCdO 4 = AgSnO2 Type 3 = Faston 250 (6.3 x 0.8 mm) with rear flange mount 6 = PCB with bifurcated terminals D: Special versions 0 = Standard 9 = Type 65.
5 SERIES Power relays 20 - 30 A 65 SERIES Contact specification F 65 - Electrical life (AC) v contact current H 65 - Maximum DC1 breaking capacity DC breaking current (A) A Cycles Resistive load - cosφ = 1 Inductive load - cosφ = 0.4 limit for 1NO+1NC types 1 normally open type 1 normally open + 1 normally closed type DC voltage (V) • When switching a resistive load (DC1) having voltage and current • values under the curve, an electrical life of ≥ 80 · 103 can be expected.
65 SERIES Power relays 20 - 30 A 65 SERIES Outline drawings Type 65.31 Type 65.61 Type 65.31- 0300 Type 65.61- 0300 A Accessories Top flange mount for types 65.31.xxxx.xxx9 065.05 065.05 065.05 065.05 with relay 065.05 with relay Top 35 mm rail (EN 60715) mount for types 65.31.xxxx.xxx9 065.07 065.07 065.07 065.07 with relay 065.07 with relay Rear 35 mm rail (EN 60715) mount for types 65.31.xxxx.xxx9 065.08 II-2018,www.findernet.com 065.08 065.08 065.08 with relay 065.