Datasheet

Features
Relays for automatic control of lighting according to
ambient light level - with separate light sensor
11.42 - 1 CO + 1 NO 12 A output contacts
Two independent outputs with individual lux setting
Selector with 4 positions:
- Standard range (threshold setting 1...80 lx)
- High range (threshold setting 20...1000 lx)
- continuous light (helpful during installation and
initial testing and for maintenance purposes)
- light off (useful for vacations)
For the first 6 working cycles (in total for channels
1 & 2) the delay time (On and Off) is reduced to
zero in order to aid installation
LED status indication
11.91 - 1 CO 16 A output contact
(+ auxiliary output for Power Module)
Daily time switch function - programmable to inhibit
main output (for energy saving)
Auxiliary output - directly driven by the photosensor
Italian patent “Light feedback compensation”
principle
Sensitivity adjustment from 2 to 150 lux
LCD status indication, set-up and programming
Internal battery for set-up/programming without
supply and for time/program back-up in case of
power failure (5 years)
SELV separation between contact and supply circuit
Double insulation between supply and light sensor
35 mm rail (EN 60715) mount
Cadmium free contact material
Cadmium free light sensor (IC photo diode)
11.42 11.91
1 CO (SPDT) + 1 NO (SPST-NO) 1 CO (SPDT) + 1 aux output*
12 / 24 ( 120 – 5 ms) 16 / 30 ( 120 – 5 ms)
250 / 400 250 / 400
3,000 4,000
750 750
2,000 2,000
750 750
1,000 1,000
2,000 2,000
1,000 (10 / 10) 1,000 (10 / 10)
AgSnO
2
AgSnO
2
230 230
——
7.4 / 2.8 6.6 / 2.9
(0.8 …1.1) U
N
(0.8 …1.1) U
N
——
100 · 10
3
100 · 10
3
1…80 2…150
20…1,000
1.25 Δ = 3 lx
15 / 30 25 / 50
–20…+50 –20 ... + 50
IP 20 / IP 54 IP 20 / IP 54
Contact specification
Contact configuration
Rated current/Maximum peak current (I
N
/I
max
) A
Rated voltage/Maximum switching voltage (U
N
/U
max
) V AC
Rated load AC1 VA
Rated load AC15 (230 V AC) VA
Nominal lamp rating (230 V): incandescent W
compensated fluorescent W
uncompensated fluorescent W
halogen W
Minimum switching load mW (V/mA)
Standard contact material
Supply specification
Nominal voltage (U
N
) V AC (50/60 Hz)
DC
Rated power VA (50 Hz)/W
Operating range V AC (50 Hz)
DC
Technical data
Electrical life at rated load in AC1 cycles
Threshold setting: Standard range lx
High range lx
Hysteresis (switching Off/On ratio)
Delay time: switching On / Off s
Ambient temperature range °C
Protection category: light dependent relay/light sensor
Approvals (according to type)
2 independent outputs
2 individual lux settings
4 position selector
Light dependent relay + time
switch
Auxiliary output (light dependent)
with 19.91 power module
available
11 Series - Light Dependent Relay 12 - 16 A
* 11.91 auxiliary output: 12 V DC, 1 W max
For outline drawing see page 8
2
III-2013, www.findernet.com
11
SERIES