User Manual Xper module 12 inch Wireless Thin Client (Rev. 1.
Copyright © This manual is copyrighted with all rights reserved. Under the copyright law, this manual may not be copied, in whole or part, without written consent of Philips. Under the law, copying includes translating into another language or format.
RF Exposure Statement This EUT is compliance with SAR for general population / uncontrolled exposure limits in ANSI/IEEE C95.1-1999 and had been tested in accordance with the measurement methods and procedures specified in OET bulletin 65 Supplement C. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. In order to avoid the possibility of exceeding the FCC radio frequency exposure limits, human proximity to the antenna shall not be less than 1.
INTRODUCTION A ruggedized wireless thin client display The Philips ProScribe is a ruggedized wireless thin client display, released with Windows XP embedded, both for ITE and medical applications. The ProScribe is designed upon PMS CV requirements. It makes use of wireless technology and thin-client computing to allow workers to access applications stored on a central server as if they were sitting behind their desktop monitor.
CONTENTS TECHNICAL INFORMATION ............................................6 INSTALLATION ....................................................................7 DIMENSIONS ........................................................................8 WEIGHT ................................................................................8 INPUT INSTRUCTION .......................................................9 right view .....................................................................9 left view ...........
1.1.0 TECHNICAL INFORMATION Processor INTEL Celeron M 1GHz Chipset INTEL 852GM+ICH4-M Graphic processor INTEL 852GM Bios Insyde software Operating System Microsoft Windows XP Embedded with SP2 Networking Built-in 802.3 network card (Intel PRO/100 VE) Built-in 802.11 b/g/n WLAN module with double integral antenna Built-in Bluetooth 2.1 (Optional) Remote Protocol Microsoft RDP / Citrix ICA Memory 1GB SDRAM on board Flash ROM 4GB flash memory module LCD Panel Characteristic 12.
2.1.0 INSTALLATION See BBRS ver. 0.8 PMS CV customer spec. paragraph. 5.1.3 cod. 4522 901 05890 While unpacking the ProScribe, inspect it and other package contents for shipping damage that could cause a fire or shock hazard. Immediately report any shipping damage to the carrier or transportation company and contact customer service for assistance. Keep all packing material in case you need to ship, store or return the monitor.
3.1.0 DIMENSIONS 313,4 60,5 235,4 (fig. 8a) 3.2.0 8 WEIGHT Weight without packaging : 2,17 Kg.
4.1.0 INPUT INSTRUCTION 4.1.1 RIGHT VIEW 1. USB 2.0 port type A 2. USB 2.0 port type A 3. Switch reset 1 3 2 (fig. 9a) 4.1.2 LEFT VIEW 1. D-SUB 9 pins male Pinning configuration: 1 Screen (PE) 2 TX+ 3 RX+ 4 24V 5 24V 6 TX7 RX8 0V 9 0V 1 (fig.
Windows XP Embedded xxxxx-xxx-xxx-xxx 2007 - 02 3 FCC ID: GZM802160 IC: 6319A-802160 AN000705000001AN000705000001AN00070 AN000209000001 9919 320 514519919 320 51451 Model No. TSM121XE-M 1.2 - 0.9A 4 9919 326 12011 INPUT RATING : 20 - 24V 4.1.4 BACK VIEW 1. Speakers 2. Desktop feet support mounting screw holes (2 x M3) 3. VESA MIS-D mounting screw holes (4 x M4) 4. TSM swing-arm and pedestal mounting screw holes (4 x M3) 1 1 2 (fig.
5.1.0 CONTROL PANEL DESCRIPTION 1. Battery LED 2. Programmable buttons 3. Track stick buttons 4. Track stick 5. Programmable buttons 6. Microphone 7. WLAN status LED 7 1 2 3 4 3 5 5 6 (fig.
6.1.0 BEFORE YOU BEGIN The ProScribe is intended for use as Windows XP embedded powered wireless thin client touch-screen device. To use your ProScribe you must have the following; ● a AC / DC power supply (24Vdc output voltage - 3,42 Adc output current) ● a wireless access point to access the corporate network or ● an Ethernet connection in case you plan to use the ProScribe on a fixed location 6.2.
6.2.2 POWER SAVING MODE To make changes to power saving setup, ● Navigate through: “START -> Settings -> Control panel -> Power Options” and select the Power Schemes that best meets your needs. ● Navigate through: “START -> Settings -> Control panel -> Tablet and Pen Settings”. ● Select the “display” TAB ● Choose the desired Brightness level Power Schemes Display 6.2.3 SET DATA AND TIME Double click on the screen display window on the task bar (in low to the right) set new data or time clock.
6.2.4 WLAN SETUP The WLAN setup is strictly dependent on the existing wireless network infrastructure. A example of WLAN setup is depicted: ● From the Ralink Wireless Utility icon on the Windows Taskbar select: “Start Windows Zero Configuration” ● Navigate through : “START -> Settings -> Control Panel -> Network Connections -> Wireless Network Connection” and select one of the available networks. ● If required, insert a network key or password.
7.1.0 DATA INPUT TO THE TOUCH SCREEN 7.1.1 TOUCH THE SCREEN Use a stylus pen to move the mouse cursor or select the desired desktop icon or menu. (fig. 15a) NOTE: The stylus pen is designed for your screen. The stylus pen can be provided upon customer request. Use of fingertip or other pointers could damage your screen. 7.2.1 LEFT OR RIGHT CLICK EMULATION Users accustomed to a mouse device often right click for quick access to command options for an icon. The stylus pen offers a similar command function.
8.1.
● Select “Tools” on the Touchkit menu. ● Press “Linearization” to start the calibration on nine points.
● Execute the calibration on the nine points. Keep pressed each point until it stops blinking.
10.0.0 CONNECTING TO A NETWORK You can setup a connection to a wireless network (WLAN) or a wired network (LAN). 10.1.0 WLAN Your ProScribe includes a wireless LAN module. 10.1.1 START A CONNECTION Method One Tap (right click) on the Ralink network icon that resides in the taskbar at the bottom of your screen.
10.1.2 When the connection is ready, you may be required to launch a remote control application to communicate between your ProScribe and the host computer.
To complete the connections with Remote Desktop Connection, you will need information including user name, password and network IP. Ask your network administrator to provide the required setup information. 10.2.1 LAN The D-SUB 9 pins is used to connect your ProScribe to a LAN network. Pinning definition for sub-D (male) Pinning configuration Pin Signal Pin Signal 1 Screen (PE) 6 TX- 2 TX+ 7 RX- 3 RX+ 8 0V 4 24 V 9 0V 5 24 V (fig.
11.0.0 FEATURED SOFTWARE APPLICATIONS Your ProScribe has a suite of applications designed to create, share, and manage your information. 11.1.1 CONTROL PANEL The Control Panel provides access to system settings allowing you to manage the properties of your ProScribe such as: ● Touch Panel Configures and calibrates your touch screen. ● Display Sets your Background, Appearance, and Backlight Time Out preferences.
11.6.1 HOT KEY UTILITY There are 4 hot keys buttons to quick launch software applications. You can customize three of these hot keys functions with the tablet and pen settings applet: ● Navigate through: “START -> Settings -> Control panel -> Tablet and Pen Settings” ● Choose tablet buttons tab ● Select the tablet button ● Tap on the change button ● Tap OK to complete NOTE: Default action: ● Button “1” -> None ● Button “2” -> None ● Button “3” -> None ● Button “4” -> None 11.7.
12.0.0 TROUBLESHOOTING 12.1.1 THE ProScribe WILL NOT TURN ON... When power is on, you will see: On the pad: Power indicator light above the screen on the right will turn green If power is on, but you still don’t see anything on the screen, wake up the pad by tapping on the screen or by pressing control buttons located on the right hand side of the screen.
13.0.0 SAFETY AND PRODUCT CARE INSTRUCTIONS 13.1.1 TO CLEAN THE SCREEN: 1. To removes dust and other particles, wipe the screen with a clean, soft, lint-free cloth. 2. For heavy duty cleaning, wipe the screen with a soft, clean cloth lightly sprayed with a commercial window cleaner that does not contain wax or abrasives. Always apply the cleaner to the cloth, not the screen. If the display contains has become greasy, substitute use isopropyl alcohol.
13.0.0 PRECAUTIONS 13.1.0 Installation The equipment should be installed near an easily accessible outlet. Do not install or leave the monitor: In places subject to extreme temperatures, for example near a radiator, heating vent, or in direct sunlight. Subjecting the LCD monitor to extreme temperatures, could cause deformations of the casing or malfunctions. In places subject to mechanical vibration or shock.
14.1.0 DISPOSAL OF THE LCD ProScribe Do not dispose of this monitor with general household waste. The fluorescent tube used in this LCD monitor contains mercury. Disposal of this monitor must be carried out in accordance with the regulations of your local sanitation authority. ● For countries in the European Union This symbol indicates that this product (including the cables, plugs and accessory) must not be disposed of with the other household waste.
15.0.0 IDENTIFICATION LABEL 1.2 - 0.9A INPUT RATING : 20 - 24V FCC ID: GZM802160 IC: 6319A-802160 2009 - 01 Type No. Xper module AN000903000001 AN000705000001AN000705000001AN00070 9919 320 514519919 320 51451 9919 326 12011 Windows XP Embedded xxxxx-xxx-xxx-xxx The identification label is visible on the back monitor side. Type number Code number (12NC) Model number CMPD12CV-I 9919 326 12011 Type N: Xper module 2009 - 01 FIMI - via S.
16.0.0 SYMBOL DESCRIPTION The following symbols may appear on the ProScribe WARNING: This symbol alerts you to important operating considerations or a potential operating condition that can be a risk for damaging equipment.
INDEX A Approved for medical applications 4 B BACK VIEW 10 BEFORE YOU BEGIN 12 C CITRIX ICA CLIENT 22 CONNECTING EXTERNAL PERIPHERALS 23 CONNECTING TO A NETWORK 19 CONTROL PANEL 22 CONTROL PANEL DESCRIPTION 11 D DATA INPUT TO THE TOUCH SCREEN 15 DIMENSIONS 8 DISPOSAL OF THE LCD ProScribe 27 E Easy to integrate, deploy and maintain 4 ETHERNET LAN SETUP 14 F FEATURED SOFTWARE APPLICATIONS 22 Flexible to fit any vertical application 4 S SAFETY AND PRODUCT CARE INSTRUCTIONS 25 SCREEN BRIGHTNESS 14 SET DATA AND
FIMI S.r.L R&D .CG1208 R2008A Specifications subject to change without notice. All dimensions shown are approximate. FIMI S.r.l. Saronno - Italy All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner Printed in Italy 4519 206 1019.