Technical data and types
Type code PVS-50-TL PVS-60-TL
Environmental
Ambient temperature range -25...+60°C (-13...140 °F) with derating above 45 °C (113 °F) with derating above 45 °C (113 °F)
Relative humidity 4%... 100% condensing
Sound pressure level, typical 75 dB(A) @1 m
Maximum operating altitude 4000 m (13123 ft) with derating above 2000 m / 6561 ft
Physical
Environmental protection rating IP65
Cooling Forced air
Dimension (H x W x D) 750 mm x 1100 mm x 261,5 mm / 29.5” x 43,3” x 10.27”
Weight 68 kg / 150 lbs (SX version)
Mounting system Single mounting bracket
Safety
Marking CE
Safety and EMC standard
I
EC/EN 62109-1, IEC/EN 62109-2, EN 61000-6-2, EN 61000-6-3, EN 61000-3-11, EN 61000-3-12
EN 62311, EN 301 489-1, EN 301 489-17, EN 300 328
Grid standard (check your sales channel for availability)
CEI 0-21, CEI 0-16, DIN V VDE V 0126-1-1, VDE-AR-N 4105, G59/3, DRRG/DEWA, Chile LV/MV
EN 50438, RD 1565, RD 413, UTE C15-7-712-1
P.O. 12.3, AS/NZS 4777.3, BDEW, NRS-097-2-1, MEA, PEA, IEC 61727, ISO/IEC Guide 67(System 5)
IEC 61683, VFR-2014, IEC 62116, Synergrid C10/11, IRR-DCC-MV, CLC-TS-50549-1/-2, G99, EN 50549-1/-2
Available product variants
Input connections with terminal blocks
+ surge arrester Type 2 in both DC and AC sides
PVS-50-TL PVS-60-TL
Input connections with terminal blocks + DC switch
+ surge arrester Type 2 in both DC and AC sides
PVS-50-TL-S PVS-60-TL-S
15 quick Input connections + fuses (single pole) + DC switch +
surge arresters Type 2 in both DC and AC sides
PVS-50-TL-SX PVS-60-TL-SX
15 quick Input connections + fuses (both poles) + DC switch +
surge arresters Type 2 in both DC and AC sides
PVS-50-TL-SX2 PVS-60-TL-SX2
Optional available
SPD Type 1 + 2 on the DC side
5)
Available Available
Display
6)
Available Available
Negative Grounding kit PVS-50/60-GROUNDING KIT PVS-50/60-GROUNDING KIT
1) Please refer to the document “String inverters – Product manual appendix”
available at www.fimer.com for information on the quick-fit connector brand
and model used in the inverter
2) Due to country specific regulations this value can be limited to the rated value
(50 kW for PVS-50-TL, 60 kW for PVS-60-TL)
3) The AC voltage range may vary depending on specific country grid standards
4) The Frequency range may vary depending on specific country grid standards
5) Article with dedicated part number, only for SX2 version
6) Inverter version with display can be selected by dedicated part number.
This option in not available in combination with the “SPD type 1+2” option
Remark. Features not specifically listed in the present data sheet are not
included in the product