Solar inverter solutions for building applications

25 Page header
Technical data and types
Type code TRIO-5.8-TL-OUTD TRIO-7.5-TL-OUTD TRIO-8.5-TL-OUTD
Environmental
Ambient temperature range -25...+60°C /-13...140°F with derating above 50°C/122°F
Relative humidity 0...100% condensing
Sound pressure level, typical 50 dBA @ 1 m
Maximum operating altitude without derating 2000 m / 6560 ft
Physical
Environmental protection rating IP65
Cooling Natural
Dimension (H x W x D)
641mm x 429 mm x 220 mm/ 25.2” x 16.9” x 8.7”
(855 mm x 429 mm x 237 mm/ 33.7” x 16.9” x 9.3” with open front cover)
Weight 25.0 kg / 55.1 lbs 28.0 kg / 61.7 lbs 28.0 kg / 61.7 lbs
Mounting system Wall bracket
Safety
Isolation level Transformerless
Marking CE (50 Hz only), RCM
Safety and EMC standard
EN 62109-1, EN 62109-2, AS/NZS3100, EN 61000-6-2, EN 61000-6-3, EN 61000-3-2,
EN 61000-3-3
Grid standard (check your sales channel for availability)
CEI 0-21, CEI 0-16, DIN V VDE V 0126-1-1, VDE-AR-N 4105, G83/2, G59/3, RD 1699, RD 413, NRS-097-
2-1, AS 4777, IEC 61727, IEC 62116, VFR 2014, EN 50549-1, EN 50549-2
Available products variants
Standard TRIO-5.8-TL-OUTD-400 TRIO-7.5-TL-OUTD-400 TRIO-8.5-TL-OUTD-400
With DC switch TRIO-5.8-TL-OUTD-S-400 TRIO-7.5-TL-OUTD-S-400 TRIO-8.5-TL-OUTD-S-400
1)
Please refer to the document “String inverters – Product manual appendix”
available at www.fimer.com for information on the quick-fit connector brand and
model used in the inverter
2)
The AC voltage range may vary depending on specific country grid standard
)
3)
The Frequency range may vary depending on specific country grid standard
Remark. Features not specifically listed in the present data sheet are not included
in the product