Solar inverter solutions for building applications

20 Page header
Technical data and types
Inverter REACT2-UNO-3.6-TL REACT2-UNO-5.0-TL
Input side
Absolute maximum DC input voltage (Vmax,abs) 575 V
Start-up DC input voltage (Vstart) 200 V (adj. 120...350 V)
Operating DC input voltage range (Vdcmin...Vdcmax) 0.7 x V
start
...575 V (min 90 V)
Rated DC input voltage (Vdcr) 390 V
Rated DC input power (Pdcr) 5000 W 6000 W
Suggested maximum DC input power 6666 W 8000 W
Number of independent MPPT 2
Maximum DC input power for each MPPT (PMPPT max)
2500 W
Linear derating [480 V≤V
MPPT
≤575 V]
3000 W
Linear derating [480 V≤V
MPPT
≤575 V]
DC input voltage range with parallel configuration of MPPT at P
acr
, not
operative battery
160 V…480 V 195 V…480 V
Maximum DC input current (Idc max) / for each MPPT (IMPPT max) 24 A / 12 A 27 A / 13,5 A
Maximum input short circuit current for each MPPT 15.0 A
Number of DC inputs pairs for each MPPT 2
DC connection type PV quick fit connector
1)
Input protection
Reverse polarity protection Yes, from limited current source
Input over voltage protection for each MPPT - varistor Yes
Photovoltaic array isolation control According to local standard
DC switch rating for each MPPT 25 A / 575 V
Battery port
Operating DC voltage range 170-575 V
N° of battery units 1, 2, 3 1, 2, 3
Charge power 1.6 kW, 3.2 kW, 4.8 KW 1.6 kW, 3.2 kW, 4.8 KW
Discharge power 2 kW, 3.6 kW, 3.6 kW 2 kW, 4 kW, 5 kW
Grid connected output side
AC Grid connection type Single-phase
Rated AC power (Pacr @cosφ=1)
3600 W 5000 W
2)
Maximum AC output power (Pacmax @cosφ=1)
3600 W 5000 W
2)
Maximum apparent power (Smax) 3600 VA 5000 VA
2)
Rated AC grid voltage (Vac,r) 230 V
AC voltage range 180...264 V
3)
Maximum AC output current (Iac max) 16 A 22 A
Contributory fault current 16 A 22 A
Rated output frequency (fr) 50 Hz / 60 Hz
Output frequency range (fmin...fmax) 45...55 Hz / 55…65 Hz
4)
Nominal power factor and adjustable range > 0.995, adj. ± 0.1 - 1 (over/under exited) > 0.995, adj. ± 0.1 - 1 (over/under exited)
Total current harmonic distortion < 3%
AC connection type AC circular connector
Grid connected output protection
Anti-islanding protection According to local standard
Maximum external AC overcurrent protection 20 A 25 A
Output overvoltage protection - varistor 2 (L - N / L - PE)
Backup output side
AC grid connection type Single-phase
Maximum apparent power (Smax) 3000 VA
Rated AC grid Voltage (Vacr) 230 V
AC Voltage range 180...264 V
4)
Maximum AC output current (Iac max) 13 A
Rated output frequency (fr) 50 Hz / 60 Hz
Output frequency range (fmin...fmax) 45...55 Hz / 55…65 Hz
5)
AC connection type Screw terminal block
Backup output protection
Maximum external AC overcurrent protection 16 A
Output overvoltage protection - varistor 2 (L-N/L-PE)
Embedded communication
Embedded physical interface Wi-Fi
5)
, 2 x Ethernet, RS485
Embedded communication protocols Modbus TCP (SunSpec), Modbus RTU (Sunspec), ABB-free@home®
Datalogger data retention 30 days
Remote monitoring Mobile app
Local monitoring Web server user interface
Environmental
Ambient temperature range -20...+55°C with derating above 50°C -20...+55°C with derating above 45°C
Relative humidity 4…100 % condensing
Acoustic noise emission level < 50 dB (A) @ 1 m
Maximum operating altitude without derating 2000 m