Solar inverter solutions for building applications
15 Page header
Technical data and types
Type code UNO-DM-4.0-TL-PLUS-Q UNO-DM-4.6-TL-PLUS-Q UNO-DM-5.0-TL-PLUS-Q UNO-DM-6.0-TL-PLUS-Q
Optional board UNO-DM-COM kit
Optional communication interface RS485 (use with meter for dynamic feed-in control), Alarm/Load manager relay, Remote ON/OFF
Optional communication protocol ModBus RTU (SunSpec), Aurora Protocol
Optional board UNO-DM-PLUS
Ethernet COM kit
Optional communication interface Ethernet, RS485 (use with meter for dynamic feed-in control), Alarm/Load manager relay, Remote ON/OFF
Optional communication protocol ModBus TCP (SunSpec), ModBus RTU (SunSpec), Aurora Protocol
Environmental
Ambient temperature range
-25...+60°C /-13...140°F
with derating above
50°C/122°F
-25...+60°C /-13...140°F with
derating above 40°C/113°F
-25...+60°C /-13...140°F with derating above 45°C/113°F
Relative humidity 0...100 % condensing
Maximum operating altitude without derating 2000 m / 6560 ft
Physical
Environmental protection rating IP 65
Cooling Natural
Dimension (H x W x D) 553 x 418 x 175 mm / 21.8” x 16.5” x 6.9”
418 mm x 553 mm x
180 mm
Weight 15 kg / 33 lbs 20,5 kg
Mounting system Wall bracket
Safety
Isolation level Transformerless
Marking CE , RCM CE (50 Hz only), RCM
Safety and EMC standard
IEC/EN 62109-1, IEC/EN 62109-2, AS/NZS 4777.2, EN 61000-6-1, EN 61000-6-2,
EN 61000-6-3, EN 61000-6-4, EN 61000-3-11, EN 61000-3-12
EN 50178,
IEC/EN 62109-1, IEC/EN
62109-2, AS/NZS 3100,
EN 61000-6-1,
EN 61000-6-3,
EN 61000-3-11,
EN 61000-3-12
Grid standard
(check your sales channel for availability)
6)
CEI 0-21, DIN V VDE V 0126-1-1, VDE-AR-N 4105, G83/2, G59/3, G98/1, G99/1,
EN 50549-1,RD 413, ITC-BT-40, AS/NZS 4777.2, C10/11, IEC 61727, IEC 62116
CEI 0-21,
DIN V VDE V 0126-1-1,
ITC-BT-40, AS 4777,
G99/1, EN 50549-1
Available products variants
Standard
UNO-DM-4.0-TL-PLUS-B-Q UNO-DM-4.6-TL-PLUS-B-Q
UNO-DM-5.0-TL-PLUS-B-QU
UNO-DM-6.0-TL-PLUS-B-G
With DC switch
UNO-DM-4.0-TL-PLUS-SB-Q UNO-DM-4.6-TL-PLUS-SB-Q
UNO-DM-5.0-TL-PLUS-SB-QU
UNO-DM-6.0-TL-PLUS-SB-G
1)
“Refer to the document “String inverter – Product Manual appendix” available at
www.fimer.com to know the brand and the model of the quick fit connector”
2)
For UK G83/2 setting, maximum output current limited to 16 A up to a
maximum output Pacr of 3600 W and a maximum apparent power of 3600 VA
3)
The AC voltage range may vary depending on specific country grid standard
4)
The Frequency range may vary depending on specific country grid standard;
CE is valid for 50Hz only
5)
As per IEEE 802.11 b/g/n standard
6)
Further grid standard will be added, please refer to FIMER Solar page for further details
Remark. Features not specifically listed in the present data sheet are not included in the
product