Solar inverter solutions for building applications

13 Page header
Technical data and types
Type code UNO-DM-1.2-TL-PLUS-Q UNO-DM-2.0-TL-PLUS-Q UNO-DM-3.0-TL-PLUS-Q UNO-DM-3.3-TL-PLUS-Q
Optional board UNO-DM-COM kit
Optional communication interface RS485 (use with meter for dynamic feed-in control), Alarm/Load manager relay, Remote ON/OFF
Optional communication protocol ModBus RTU (SunSpec), Aurora Protocol
Optional board UNO-DM-PLUS
Ethernet COM kit
Optional communication interface
Ethernet, RS485 (use with meter for dynamic feed-in control),
Alarm/Load manager relay, Remote ON/OFF
Optional communication protocol ModBus TCP (SunSpec), ModBus RTU (SunSpec), Aurora Protocol
Environmental
Ambient temperature range
-25...+60°C /-13...140°F
with derating above
50°C/122°F
-25...+60°C /-13...140°F
with derating above
50°C/122°F
-25...+60°C/-13...140°F con
derating above 50°C/122°F
-25...+60°C /-13...140°F with
derating above 50°C/122°F
Relative humidity 0...100 % condensing
Acoustic noise emission level 50 dBA @ 1 m
Maximum operating altitude without
derating
2000 m / 6560 ft
Physical
Environmental protection rating IP 65
Cooling Natural
Dimension (H x W x D) 553 x 418 x 175 mm / 21.8” x 16.5” x 6.9”
Weight 15 kg / 33 lbs
Mounting system Wall bracket
Safety
Isolation level Transformerless
Marking CE , RCM
Safety and EMC standard
IEC/EN 62109-1, IEC/EN 62109-2, AS/NZS 4777.2, EN 61000-6-1,EN 61000-6-2, EN 61000-
6-3, EN 61000-6-4, EN 61000-3-2, EN 61000-3-3
Grid standard
(check your sales channel for avail-
ability)
5)
CEI 0-21, DIN V VDE V 0126-1-1, VDE-AR-N 4105, G83/2, G59/3, G98/1, G99/1, EN 50549-1, RD 413, ITC-BT-40,
AS/NZS 4777.2, IEC 61727, IEC 62116
Available products variants
Standard UNO-DM-1.2-TL-PLUS-B-Q UNO-DM-2.0-TL-PLUS-B-Q UNO-DM-3.0-TL-PLUS-B-Q UNO-DM-3.3-TL-PLUS-B-Q
With DC switch UNO-DM-1.2-TL-PLUS-SB-Q UNO-DM-2.0-TL-PLUS-SB-Q UNO-DM-3.0-TL-PLUS-SB-Q UNO-DM-3.3-TL-PLUS-SB-Q
1) “Refer to the document “String inverter – Product Manual appendix” available
at www.fimer.com to know the brand and the model of the quick fit connector”
2) The AC voltage range may vary depending on specific country grid standard
3) The frequency range may vary depending on specific country grid standard; CE
is valid for 50 Hz only
4) As per IEEE 802.11 b/g/n standard
5) Further grid standard will be added, please refer to FIMER Solar page for
further details
Remark. Features not specifically listed in the present data sheet are not included in the
product