Product Brochure
Did you know that a clogged air filter*
Reduces the overall air flow in your home
Blocks the cooling coil, reducing effectiveness
Increases the operating cost of your HVAC system
Causes dirt to accumulate on the fan blades, increasing your energy costs
Leads to frost build up on the cooling coil or total blockage of air flow
Permits dirt to bypass the filter, where it soils and blocks the blower fan
Fails to capture contaminants, leading to poor indoor air quality in your home
In extreme cases, can even be sucked right into the blower assembly
Causes excessive dirt build up in your air duct system leading to mold or allergen problems
* A study of 40,000 homes by the City of Tallahassee, Florida, found the second most common reason for high summer electric utility
bills (the most common reason being an incorrect “fan” setting) was a clogged air filter (floridapsc.com/publications/consumer/brochure/
113CausesHighSummerUtilityBills.pdf). Furthermore, dirty filters are the primary cause of HVAC equipment failure
(diamondcertified.org/report/valley-heating-cooling-electrical-0/article/make-sure-you-choose-the-right-air-filtersfor-your-hvac-system).
Power Requirements: Model FS-245-B: Four included AA batteries, or optional CA-360 6 VDC wall
adapter (Battery life approximately one year)
Model FS-245-C: 15 to 24 VAC/DC @ 250 mA max via conduit
Differential Pressure Range: Near zero to 4.0" w.c.
Clog Filter Trigger Point: 1.5 to 2 times initial differential pressure (at the recommended setting on the
SERVICE FILTER control)
Insertion Depth into Duct: Does not extend into duct
Local Alert Output: Audible Beeper and LED indication
Wired Output: Pulsing 0 V to 5 VDC @ 18 mA max upon clog or low battery alert
Relay Output: Optional One Form C contact set @ 500 mA max – Model FS-245-C
Text & E-Mail Notification**: User configurable SMS text messaging and e-mail
Indicators: Green / Yellow / Red Status LED and Audible Beeper
Electrical Connections: Power - 2.5mm barrel jack mates to AC Adapter – Model FS-245-B, or
Power - Conduit into terminal block, 14-30 AWG – Model FS-245-C
Output - Conduit into terminal block, 14-30 AWG – Model FS-245-C
Temperature Range: 32
o
to 122
o
F (0
o
to 50
o
C), Operating
-40
o
to 257
o
F (-40
o
to 125
o
C), Storage
Humidity: 80% RH, Non-condensing
WiFi: 2.4-GHz IEEE 802.11b/g compatible
WiFi Authentication: Secure using WPA-PSK (TKIP), and WPA2-PSK (AES)
Monitor Dimensions: 6” x 4 5/8” x 1 1/2”
** Requires subscription to AirFilterSentry Notification Service, Internet connection,
and wireless router.
Specifications are subject to change without notice.
Model Number
Description
FS-245-B
FILTERSCAN, WiFi Battery or Adapter Operated
FS-245-C
FILTERSCAN, 15 to 24V AC/DC Operated
CA-360
Adapter, 6.0 VDC
CA-4DP
Kit, Tubing, Differential Mounting
Contains FCC ID Number: T9J-RN171
Contains IC Certification/Registration Number IC: 6514A-RN171
Contient IC Certification / d'enregistrement les IC: 6514A-RN171 FSWiFiPIS151113
FILTERSCAN
®
WiFi Air Filter
Monitor
Subscriber's
Smart Phone
PC - Laptop -
Notebook
Tablet
Subscriber's
HVAC
Technician
Smart Phone
Wireless Internet
Router
CleanAlert Internet Cloud Server Database
FILTERSCAN
®
status is sent to the database periodically and can be sent upon demand from the
FILTERSCAN by depressing the SEND button. Status includes percentage of air filter life used,
battery condition, system error, time since last filter service, and software version. Software updates
can be performed remotely from the database to each individual FILTERSCAN WiFi Air Filter
Monitor.
Specifications