Installation Guide
18 
cause the FILTERSCAN WiFi Home Air Filter Monitor to issue an alarm at a lower level of filter 
clogging (less energy consumption). Turning the SERVICE FILTER adjustment knob counter-clockwise 
will cause the FILTERSCAN WiFi Home Air Filter Monitor to issue an alarm at a higher level of filter 
clogging (more energy consumption). See the FAQ Section for further information. 
Operation - FILTERSCAN WiFi Home Air Filter 
Monitor 
System Monitoring  The STATUS LED will blink green approximately once per minute (called 
a heartbeat) to indicate that the unit is functioning properly. Usually the 
FILTERSCAN WiFi Home Air Filter Monitor will be in the standby 
mode, conserving power. It wakes up periodically to monitor air filter 
condition, battery level, and system operation. If no alarm conditions are 
detected, the FILTERSCAN WiFi Home Air Filter Monitor goes back 
to sleep after several minutes of monitoring.  
  NOTE: Should there be a power failure the FILTERSCAN WiFi Home 
Air Filter Monitor will save all parameters such as the clean air filter 
calibration and the current state of the air filter. When power is restored, 
the FILTERSCAN WiFi Home Air Filter Monitor will continue 
operation with no user action required. The same applies when replacing 
depleted batteries. 
Alarm Modes  The FILTERSCAN WiFi Home Air Filter Monitor provides both 
audible and visual local alarms indicating a clogged air filter, a low battery, 
or a system malfunction. In addition, the AirFilterSentry Notification 
Service allows remote monitoring* of system conditions. *Creating an 
account in the AirFilterSentry Notification service is required to enable this feature. 
 NOTE: The HVAC system blower fan must be running when the 
FILTERSCAN WiFi Home Air Filter Monitor attempts to check air 
filter condition. Since the FILTERSCAN WiFi Home Air Filter Monitor 
checks the air filter condition periodically, it may take several days to 
detect, trigger, and alert a clogged filter condition. 
NOTE: The FILTERSCAN WiFi Home Air Filter Monitor has a light 
sensor which prevents audible alarms when there is no light present at the 
Monitor location. This prevents awaking occupants while sleeping and 
prevents needless beeping in a crawl space, attic, or other unoccupied 
location. The visual Status LED will still operate normally regardless of 
lighting conditions. 
  Clogged Air Filter  When the FILTERSCAN WiFi Home Air Filter Monitor detects a 
clogged air filter, an alert condition is triggered. The red STATUS LED will 
illuminate, blinking five times approximately every ten minutes until the 
alert condition is reset. There will also be an audio alert which 
corresponds to the visual alert indication. NOTE: Allowing this alarm 
condition to go on indefinitely will drain the batteries (-B model only). The 
clogged filter alert is reset by following the instructions in the section 
"Calibrating When Installing a New Air Filter" below.  In addition, a text 
and or email will be sent to a designated person if you have signed up for 
the AirFilterSentry Notification Service. 
NOTE: A new or cleaned air filter should always be installed whenever the 
CALIBRATE (depressing the Reset button) operation is performed. 