Instructions / Assembly
5
fillrite.com | tuthill.com
INSTALLATION AND OPERATION MANUAL
IMPORTANT! Do not use check valves or foot valves; valves reduce rate of flow and performance of the pump.
Nozzle Boot Installation
Mounting peg
Mounting bolt
Pump Foot Installation
Install the nozzle boot using the supplied attaching bolt. Note that the bolt is
inserted through the hole closest to the nozzle opening, and the boot is then
positioned so the peg on the pump mounting surface inserts in the top second
hole of the boot. This allows for correct alignment of the nozzle when inserted into
the boot.
The mounting foot is bolted to the bottom of the pump using
the four supplied socket head cap screws. Mount the foot
with the bolt flanges inboard of the mounts on the pump as
illustrated. Torque to 50 in lb. with 4 mm hex key.