Datasheet
Revised 08/12
8
TECHNICAL INFORMATION FOR TGS3870
0.1
1
10
0 10 20 30 40 50 60
Methane 1000ppm
Methane 3000ppm
Methane 9000ppm
Rs/Ro
Time (days)
test
0.01
0.1
1
10
0 10 20 30 40 50 60
CO 100ppm
CO 300ppm
CO 900ppm
Rs/Ro
Time (days)
test
Figure 11a - Effects of exposure to 30ppm CO for 30 days
(Ro= Rs in 3000ppm methane prior to CO exposure, VH =0.9)
Figure 11b - Effects of exposure to 30ppm CO for 30 days
(Ro= Rs in 100ppm CO prior to CO exposure, VH =0.2)
3. Reliability
3-1 False alarming test
To demonstrate the sensor’s behavior under
continuous low level exposure to CO, samples were
tested according to the procedure detailed in UL2034,
Sec. 41.1(c)-Stability Test. Test samples were exposed
to 30ppm of CO continuously for 30 days under
standard circuit conditions. As this data shows, no
signicant change can be seen in CO and methane
sensing characteristics as a result of continuous low
level exposure to CO.
Rs/RoRs/Ro