Datasheet
Revised 08/12
10
TECHNICAL INFORMATION FOR TGS3870
0.1
1
10
0 5 10 15 20 25 30 35 40
Methane 1000ppm
Methane 3000ppm
Methane 9000ppm
Rs/Ro
Temperature (˚C)
test
1 hour after test
0.01
0.1
1
10
0 5 10 15 20 25 30 35 40
CO 100ppm
CO 300ppm
CO 900ppm
Rs/Ro
Time (days)
test
1 hour after test
Figure 13b - Corrosion durability for CO sensing
(Ro = Rs in 100ppm of CO prior to test, VH =0.2)
3-3 Corrosion test
To demonstrate the durability of TGS3870 against
corrosion, samples were subjected to test conditions
called for by UL2034, Sec. 57-Corrosion Test. Over
a three week period, a mixture of H2S 100ppb, Cl2
20ppb, and NO2 200ppb was supplied to the sensor
at a rate sufcient to achieve an air exchange of 5
times per hour. Measurements in the listed gases
were taken one hour after sensors were temporarily
removed from the test mixture and returned to
normal air.
No signicant effects can be seen on the CO sensing
characteristics of the sensor during and after this
test, while methane sensing characteristics were
unaffected by this test.
Rs/Ro Rs/Ro