3-3 Corrosion test
To demonstrate the durability of TGS3870 against
corrosion, samples were subjected to test conditions
called for by UL2034, Sec. 57-Corrosion Test. Over
a three week period, a mixture of H2S 100ppb, Cl2
20ppb, and NO2 200ppb was supplied to the sensor
at a rate sufcient to achieve an air exchange of 5
times per hour. Measurements in the listed gases
were taken one hour after sensors were temporarily
removed from the test mixture and returned to
normal air.
No signicant effects can be seen on the CO sensing
characteristics of the sensor during and after this
test, while methane sensing characteristics were
unaffected by this test.