User Guide
FS-8700-88 Envirotronics SystemsPlus            Page 22 of 49 
FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldServer.com 
Tel: (408) 262-2299 Fax: (408) 262-9042 Toll_Free: 888-509-1970 email: support@fieldServer.com 
4.4.43.  Map Descriptor Example 40 - edit alarms 
// Client Side Mao Descriptors 
Map Descriptor             
Map_Descriptor_Name,  Data_Array_Name,  Data_Array_Offset,  Function,  Node_Name,  SysPlus_Cmd,  Length 
Edit_Alarms,  Edit_Alarms,  0,  wrbx,  SYSPLUS_01,  Ed_Alarms,  1 
Triggger this command by writing any value to Data_Array_Name at Data_Array_Offset. 
4.4.44.  Map Descriptor Example 41 - set circulators = Boolean 
// Client Side Mao Descriptors 
Map Descriptor             
Map_Descriptor_Name,  Data_Array_Name,  Data_Array_Offset,  Function,  Node_Name,  SysPlus_Cmd,  Length 
Set_Circs,  ManualControl,  0,  wrbx,  SYSPLUS_01,  Set_Circs,  1 
Write a value of 1 for “on” or 0 for “off” to Data_Array_Name at Data_Array_Offset to trigger this command. 
4.4.45.  Map Descriptor Example 42 - set lights = Boolean 
// Client Side Mao Descriptors 
Map Descriptor             
Map_Descriptor_Name,  Data_Array_Name,  Data_Array_Offset,  Function,  Node_Name,  SysPlus_Cmd,  Length 
Set_Lights,  ManualControl,  1,  wrbx,  SYSPLUS_01,  Set_Lights,  1 
Write a value of 1 for “on” or 0 for “off” to Data_Array_Name at Data_Array_Offset to trigger this command. 
4.4.46.  Map Descriptor Example 43 - select program program_num 
// Client Side Mao Descriptors 
Map Descriptor             
Map_Descriptor_Name,  Data_Array_Name,  Data_Array_Offset,  Function,  Node_Name,  SysPlus_Cmd,  Length 
Select_Program,  Program_Num,  0,  wrbx,  SYSPLUS_01,  Select_Prog,  1 
A program_num  value must be written to Data_Array_Name at Data_Array_Offset to trigger this command. 