 Parameter   Description 
Cache - Created 
The number of times a cache Map Descriptor containing outdated 
data has been polled resulting in the creation of a new cache Map 
Descriptor. See Error! Reference source not found. 
Cache - Bumped 
The number of expired cache blocks. See Error! Reference 
source not found. 
Pex Write Thru 
Writes are never cached - the external device is put on hold while 
the FieldServer resends the message to the PLC and waits for the 
response. When the FieldServer receives the response from the 
PLC it in turn responds to the external device. This operation is 
counted as a PEX Write thru. 
Server Response Max 
The maximum time that the FieldServer has taken since the last 
reset to receive a message from an external device, poll the PLC 
and respond to the external device. The SCADA Hold Timeout 
parameter should be set higher than this limit 
Server Response Avg 
This is the average time that the FieldServer has taken since the 
last reset to receive a message from an external device, poll the 
PLC and respond to the external device. Reconfigure if response 
times are slow. 
Link Control 
Who-Is-Router-To-Network 
I-Am-Router-To-Network 
Reject-Msg-To-Network 
BACnet specific – see Driver Manual. 
Messages Reconstructed  Metasys Specific – see Driver Manual. 
Unsupported Property  The driver encountered an unsupported property in a message. 
Unsolicited Messages Recd  A message was received without the driver polling for it. 
Single Write  A write data message containing a single data element. 
Single Item Read  A read data message requesting a single data element. 
Block Write  A write message containing a block of data elements. 
Block Read  A read message requesting a block of data elements. 
Sequence Error 
Messages containing sequence numbers received out of 
sequence. 
Data Object Startup  Data requested from a node in start-up mode. 
Expedite Read 
Expedite Write 
The number of Map Descriptors given the highest priority to 
complete a read/write first. 
Fasttrack Read 
Fasttrack Write 
The number of Map Descriptors given a higher priority to complete 
a read/write as soon as possible. 
Fasttrack Overrun Read 
Fasttrack Overrun Write 
The number of times the buffer holding fasttrack read/write Map 
Descriptors overflowed. 
Max Read Response Time 
Min Read Response Time 
Avg Read Response Time 
Maximum/Minimum/Average time in seconds that passed before a 
response was received to a read message sent by a driver acting 
as a Client. 
Max Write Response Time 
Min Write Response Time 
Avg Write Response Time 
Maximum/Minimum/Average time in seconds that passed before a 
response was received to a write message sent by a driver acting 
as a client. 
Max Passthru Response Time 
Min Passthru Response Time 
Maximum/Minimum/Average time in seconds to receive a 
response to a poll sent using the Passthru mechanism. 