User Manual

Specifications
Sensing element: Enhanced infrared photo optics
Sensor life: 10 years
Refrigerants: HFC, CFC, HCFC, and blends 
Sensitivity: Min (Stationary): 0.1oz/yr (3g/yr)
Max (Stationary): >1.05oz/yr (>30g/yr)
Min (In motion): 0.18oz/yr (5g/yr)
Max (In motion):  >1.05oz/yr (>30 g/yr)
After exposure to (50g/yr): 0.1 oz/yr (3g/yr)
In poluted environment: 0.1 oz/yr (3g/yr)
Response time: 1 second
Recovery time: ~4 seconds
Auto off: 10 minutes after no activity
Battery: 3.7VDC(nominal), rechargeable lithium
ion user-replaceable battery.
Battery life: 8 hours continuous use prior to  need-
ing a charge. Degradation (30%) after 500
charge/discharge cycles or two years, whichever
comes first.
Low battery LED: Lights when approximately 1
hour of battery life remains.
Charge time: Less than 4 hours (either charger)
Operating environment: 32ºF (0°C) to 104ºF
(40°C) at <75%RH (non-condensing)
Storage environment: <80%RH meter and batt.
For 80% battery recovery:
-4ºF (-20°C) to 140ºF (60°C) less than 1 month
-4ºF (-20°C) to 113ºF (45°C) less than 3 months
-4ºF (-20°C) to 68ºF (20°C) less than 1 year
Notice of Compliance
This instrument complies with the specifications
for an indicating, locating leak detector as described
by  the  european  standard  EN  14624,  EN  14624
(2005)  with  the  assumption that  the speed  specifi-
cation  in section  7.2  should  read  as  "2.0  cm/s"  as
was indicated to us by A. Beatrix Alke, project man-
ager of Deutsches Institut fur Normung. 
More Products From Fieldpiece
Modular Expandability
Modular  expandability  is  ability  for  accessory
heads  and  meters  to  change  configurations  to
match the various needs of an HVAC/R technician.
Accessory  heads  (the  sensors)  send  out  a  mV
signal, which represents the value of the measure-
ment, to whatever meter is attached to it. Heads can
attach directly to the top of a Stick meter, DL3 data
logger, or EHDL1. They can also plug into any meter
with mV ranges using ASLS2 leads.
Warranty and Service
The product is warranted to the original purchas-
er against defects in material or workmanship for a
period  of  one  (1)  year  from  the  date  of  purchase.
During the  warranty period,  Fieldpiece  Instruments
will, at its option, replace or repair the defective unit. 
This warranty does not apply to defects resulting
from abuse, neglect, accident, unauthorized repair,
alteration,  or  unreasonable  use  of  the  instrument.
Any  implied  warranty  arising  out  of  the  sale  of
Fieldpiece's  products  including  but  not  limited  to
implied warranties of merchantability and fitness for
purpose  are  limited  to  the  above.  Fieldpiece  shall
not  be  liable  for  incidental  or  consequential  dam-
ages.
Return any defective SRL2 to Fieldpiece for war-
ranty service along with proof of purchase. Contact
Fieldpiece for out of warranty repair charges. 
C
AT.III
300V
4
00A
CLAMP
ACH4
AC Current
Clamp
1AAC / 1mVAC
4
00AAC MAX
!
A
i
r
V
e
l
o
c
i
t
y
&
T
e
mp
e
r
a
t
u
r
e
H
e
a
d
E
n
g
l
i
s
h
R
E
A
D
L
O
B
A
T
T
O
N
L
C
D
X
1
0
0
A
v
e
r
a
g
e
(
1
6
s
e
c
)
M
e
t
r
i
c
R
e
a
l
t
i
m
e
A
A
V
3
A
U
T
O
-
O
F
F
E
n
g
l
i
s
h
M
e
t
r
i
c
F
t
/
m
i
n
M
/
s
K
M
/
h
r
M
P
H
º
F
º
C
O
F
F
A
O
X
2
Co
m
b
us
t
i
o
n
C
h
e
c
k
%
O
%
C
O
T
E
M
P
O
N
G
A
S
O
I
L
L
o
B
a
t
t
°
C
°
F
A
U
T
O
O
F
F
S
T
A
B
L
E
F
u
e
l
T
y
p
e
2
2
T
/
C
C
A
L
A
U
T
O-
O
F
F
T/
C
C
a
l
S
T
A
B
L
E
P
r
e
ss
u
r
e
T
e
m
p
S
H
o
r
S
C
O
N
L
O
B
A
T
T
R
e
f
r
i
g
e
r
a
ti
on
S
u
p
e
r
h
e
a
t
a
n
d
S
u
b
cool
in
g
E
N
GL
I
S
H
M
E
T
RI
C
R1
3
4
A
R4
0
4
A
S
e
t
A
T
M
A
S
X
2
4
S
H
S
C
v35, ©Fieldpiece Instruments, Inc. 2013
Lithium Battery Care
The  SRL2  contains  a  very  powerful  lithium  ion
battery. For a long battery life and safe operation,
you must observe the following:
Cautions
1. Do not expose the battery to temperatures high-
er than 140ºF (60°C). 
2. Do not charge the battery in or nearby heated
places, such as fire, hot vehicles, or direct sun-
light. 
3. Do not solder directly on battery.
4. Do not expose the battery to direct impact or
throw it. 
5. Do not get the battery wet.
6. Do not deform or pierce the battery in any way.  
7. If there is any battery leakage, do not touch the
battery. In the case that electrolyte gets into the
eyes, flush with fresh water, do not rub, and see
a physician immediately. 
8. Replace immediately if there is any deformity,
bad smell, color change, or other abnormality.
9. The battery is user-replaceable and can be pur-
chased at most electronic stores. The following
batteries are known to be compatible with the
SRL2: Fuji Film:NP-120, PENTAX: DLI-7,
RICON: DB-43
Charging
Two  chargers  are  included  with  the  SRL2.  The
AC  charger  plugs  into  a  wall  outlet  and  the  car
charger plugs into a car cigarette lighter DC plug.
1. The battery is partially charged when packaged.
Fully charge the battery before first use. 
2. The LOW-BATT LED will light red when the bat-
tery is low. 
3. To recharge the SRL2, plug one end of the
charger into the top of the SRL2 and the other
into the power source. LOW-BATT will blink
while charging until the battery is fully charged.
When the SRL2 battery is fully charged, LOW-
BATTturns off. 
4. Charge within operating environment specified
in the Specifications section in this manual. 
5. Avoid frequent full discharges. Several partial
discharges with frequent recharges are better
for lithium-ion batteries. Unlike nickel-based bat-
teries they have no charge memory, and do not
need to be discharged before charging.
Storage
The battery should have a 40%-50% charge dur-
ing  prolonged  storage  of  a  month  or  longer.  See
Specifications section in this manual for proper stor-
age environment. 
Battery life is dramatically reduced if the battery
is stored fully charged and/or at high temperatures.
Included Equipment
Use model RRE2 when detecting in tight spaces,
such  as  through  a  condenser  grille.  Model  RFE2
extends the wand to 25.5” (65cm). The blow mold-
ed case, model holds accessories and chargers.
All  accessories  shown  are  included  with  the
SR2K7. 
Standalones from Fieldpiece
The SRL2 refrigerant leak detector is designed
for  HVAC/R  technicians.  Here  are some  other
standalone products from Fieldpiece Instruments.
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
P
1
P
1
P
2
Z
ERO
HOLD UNIT
ON/OFF
P
2
88.88
88.88
A
PO
88.8888.88
inWC
mmWC
m
bar
p
si
HOLD
PRESS FOR 1 SECOND
A
UTO-OFF BATTERY
C
HECK
S
C57
AUTO OFFTRUE RMS
C
AT III
600V
TEMP
K-TYPE
30V
M
AX
SC57
OO
FF
FF
W
IRELESS ENABLED
SEL
SYNC
SDMN5
Dual Port
Manometer
SDP2
Dual In-duct
Psychrometer
SC57
All-in-one
Wireless
Clamp-on Meter
9”(23cm) Needle Tip
Probe  model RRE2
9
”(23cm) Flex
Extension
model RFE2
Blow molded Carrying Case
w/ RRE2 and RFE2
Model ABMK3