Brochure

General
Display: LCD (5 inches diagonal)
Backlight: Blue (adjustable duration)
Over Range Display: OL for pressure, - - - - for temperature
Auto Power Off: 30 minutes of inactivity (adjustable)
Maximum Manifold Pressure: 65 Bar (940 Psig)
Battery Type: 6 x AA alkaline
Battery Life: 350 hours typical (without vacuum, backlight, and wireless)
Radio Frequency: 2.4 GHz
Wireless Range: 350 feet (106 meters) line of sight
Distance decreases through obstructions
Data Port: Micro USB (for extracting logged data or updating firmware)
Operating Environment: 32°F to 122°F (0°C to 50°C) at <75% RH
Storage Environment: -4°F to 140°F (-20°C to 60°C) at <80% RH
(with battery removed)
Temperature Coefficient: 0.1 x (specified accuracy) per °C
(0°C to 18°C, 28°C to 50°C), per 1.8°F (32°F to 64°F, 82°F to 122°F)
Weight: 4.03 lbs (1.83 kg)
Water Resistant: Designed to IP54
US Patent: www.fieldpiece.com/patents
Refrigerants: New refrigerants are continually being added so be sure to visit
www.fieldpiece.com for the latest firmware
Pressure
Sensor Type: Absolute pressure sensors
Port Type: (3) 1/4” standard NPT male flare fittings (SM380V)
(1) 3/8” and (3) 1/4” standard NPT male flare fittings (SM480V)
Pressure Range and Units: 870 Psig (English), 60.00 Bar (Metric), 6.000 MPa
(Metric), and 6000 kPa (Metric)
Negative Pressure Range and Units:
29 inHg (English), 74 cmHg (Metric)
Resolution: 0.1 Psig; 0.01 Bar; 0.001 MPa; 1 kPa; 0.1 inHg; 1 cmHg
Negative Pressure Accuracy:
29 inHg to 0 inHg: ±0.2 inHg;
74 cmHg to 0 cmHg: ±1 cmHg
Pressure Accuracy:
0 Psig to 200 Psig: ±1 Psig;
200 Psig to 870 Psig: ±(0.3% of reading + 1 Psig);
0 Bar to 13.78 Bar ±0.07 Bar;
13.78 Bar to 60.00 Bar: ±(0.3% of reading + 0.07 Bar);
0 MPa to 1.378 MPa: ±0.007 MPa;
1.378 MPa to 6.000 MPa: ±(0.3% of reading + 0.007 MPa);
0 kPa to 1378 kPa: ±7 kPa;
1378 kPa to 6000 kPa: ±(0.3% of reading + 7 kPa)
Temperature
Sensor Type: Type K thermocouple
(nickel chromium/nickel aluminum)
Jack Type: (3) Type K thermocouple
Range: -50°F to 257°F (-46°C to 125°C), limited by the thermocouple specification.
Display range is -95°F to 999.9°F (-70°C to 537.0°C)
Resolution: 0.1°F (0.1°C)
Accuracy: Shown accuracies are after field calibration.
±(1.0°F) -95°F to 200°F, ±(2.0°F) 200°F to 999.9°F;
±(0.5°C) -70°C to 93°C, ±(1.0°C) 93°C to 537.0°C
Deep Vacuum
Sensor Type: Thermistor
Port Type: (3) 1/4” standard NPT male flare fittings (SM380V)
(1) 3/8” and (3) 1/4” standard NPT male flare fittings (SM480V)
Range and Units:
50 to 9999 microns of mercury (English)
6 to 1330 Pascals (Metric)
0.06 to 13.3 mBar (Metric)
50 to 9999 mTorr (Metric)
0.05 to 10 Torr (Metric, equivalent to mmHg)
Best Resolution:
1 micron of mercury (below 2000 microns)
1 Pascal (below 250 Pascals)
0.001 mBar (below 2.5 mBar)
1 mTorr (below 2000 mTorr)
0.001 Torr (below 2.5 Torr)
Accuracy @ 77°F (25°C):
±(5% of reading + 5 microns of mercury)
±(5% of reading + 1 Pascal)
±(5% of reading + 0.01 mBar)
±(5% of reading + 5 mTorr)
±(5% of reading + 0.005 Torr)
Wireless Compatibility
Latest compatibility at www.fieldpiece.com
Job Link System Minimum Device Requirement:
BLE 4.0 devices running iOS 7.1 or Android
TM
Kitkat 4.4
Wireless Measurement Source Assignments:
Suction line temperature: Fieldpiece model JL3PC (set to blue)
Liquid line temperature: Fieldpiece model JL3PC (set to red)
Supply air psychrometer: Fieldpiece model JL3RH (set to blue)
Return air psychrometer: Fieldpiece model JL3RH (set to red)
Refrigerant weight scale: Fieldpiece models SRS3, SRS3P
SM380VINT SM480VINT
What’s included
SM380V or SM480V SMAN Refrigerant Manifold
(2) TC24 Type K Pipe Clamp Thermocouples
(1) ATA1 Type K Bead Thermocouple w/Clip
(1) ANC11 Padded Drawstring Case
SMAN
Refrigerant Manifold Specifications
*
* The SM380V and SM480V have the same specifications and features, with the only difference being their number of ports.
© Fieldpiece Instruments, Inc 2019.
Fieldpiece Instruments B.V.
Kingsfordweg 151
1043GR Amsterdam
The Netherlands
+34 659.181.882 |+44 1604 654164