Overview of Primary Product

How To Use Your Multimeter:
Voltage
Resistance (ohms)
& Continuity Beeper
(beeps at resistances <100)
Current >200µA
AC Current with Clamp
(Clamp coverts one amp of AC current
into one milli-volt of AC voltage)
Accessories
NOTE: For DC voltage and currents, set the meter to the DC parameter instead of AC as shown above. For all ranges and functions choose range
just above value you expect. If display reads "1" (overload), select a higher range. If display shows less than three numbers, select a lower range
for better resolution.
Current <200µA
User Maintance
All repairs must be performed by a factory
service center or qualified instrument service
personnel.
Battery Replacement
When the multimeter displays the " " the
battery must be replaced to maintain proper
operation. To prevent electrical shock, turn off
the meter and disconnect leads before removing
the back cover.
Obtaining Service
Call Fieldpiece for an RMA# (714 257-9060)
and send the meter freight prepaid to Fieldpiece
Instruments. For warranty service also send
proof of date of purchase. For out-of-warranty
service send $25, check or money order. Do not
send cash. The meter will be completely repaired
or replaced, at the option of Fieldpiece, and
returned to you via least cost transportation.
Response time is typically 24 hours after receipt
of meter.
Limited Warranty
This meter is warranted against defects in
material or workmanship for one year from
date of purchase. Fieldpiece will replace or
repair the defective unit, at its option, subject
to verification of the defect.
This warranty does not apply to defects
resulting from abuse, neglect, accident,
unauthorized repair, alteration, or
unreasonable use of the instrument.
ANY IMPLIED WARRANTIES ARISING OUT
OF THE SALE OF A FIELDPIECE
INSTRUMENT’S PRODUCT, INCLUDING BUT
NOT LIMITED TO IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, ARE LIMITED TO THE
ABOVE. FIELDPIECE SHALL NOT BE LIABLE
FOR LOSS OF USE OF THE INSTRUMENT OR
OTHER INCIDENTAL OR CONSEQUENTIAL
DAMAGES, EXPENSES, OR ECONOMIC
LOSS, OR FOR ANY CLAIM. FOR SUCH
DAMAGE, EXPENSES, OR ECONOMIC LOSS.
State laws vary. The above limitations or
exclusions may not apply to you. This
warranty gives you specific legal rights, and
you may also have other rights which vary
from state to state.
Air Velocity
& Temperature
Head
English
READLOBATT
ON
LCDX
100
Average
(16sec)
Metric
Real
time
AAV3
AUTO-
OFF
English Metric
Ft/min M/s
KM/hrMPH
ºF ºC
OFF
Converts
1micronof
mercury to
1mVDC
Vacuum
Gauge
Accessory
Head
AVG2
INC
DEC
ON
LOBATT
STABLE