User Guide
K-type Thermocouple
Model: ATB1
Max: 400ºF
OPERATOR’S MANUAL
Description
The ATB1, K-Type, thermocouple can be used
continously to take temperature readings up to
400ºF and a one time use of 482ºF. The ATB1 can
be used with any thermometer which accepts a K-
type thermocouple.
The velcro allows the user to strap the ATB1 to a
pipe, allowing the user to take hands free, more
accurate measurement. The ATB1 also comes with
a wrap tab making it easy to wind and store the
thermocouple.
Operation
To use the ATB1 plug it into any thermometer
accepting a K-type thermocouple and adjust the
device to the appropriate settings. To use velcro
strap, Insert the thermocouple through the velcro as
shown below and strap it to the pipe.
Calibration
Due to variances in the thermocouple wire and
other parts of the system, a field calibration should
be conducted before use. Field calibration typically
gives +/- 1ºF overall accuracy. The instructions for
this calibration should be in the operating manual
for the thermometer.
Specifications
Thermocouple Conductors: K-type Nickel
Chromium/Nickel Aluminum, 2300ºF maximum
(insulation limits max. see probe insulation).
Accuracy: -50ºF to 400ºF +/- 4ºF,
Range: -50ºF to 400ºF maximum continous oper-
ation. Single exposure use at 482°F.
Probe insulation: While calibration and atmos-
phere will affect maximum useful temperature in
applications, this insulation is designated to
withstand a maximum continuous use at 400°F
(240°C) and a single exposure use at 482°F
(250°C).
Plug: K-Type Thermocouple male mini plug.
Broken Wires:
Due to frequent bending, the K-type thermocou-
ple wire may break or come loose, typically near the
plug. To repair, cut and strip the thermocouple wire
near the plug. The red wire is the (-) wire and it
belongs on the wider of the two plugs. Loosen the
screws on plugs and wind the conductors around
the appropriate screws and tighten. Finally, position
the plugs into the tab and screw the tab back togeth-
er.
Warranty
The ATB1, K-Type, thermocouple is warranted
against manufacturer’s defects for one year. This
warranty does not apply to defects resulting from
abuse, neglect, accident, unauthorized repair, alter-
ation, or unreasonable use of the instrument. Any
implied warranty arising out of the sale of
Fieldpiece's products including but not limited to
implied warranties of merchantibility, and fitness for
purpose, are limited to the above. Fieldpiece shall
not be liable for incidental or consequential dam-
ages.
Service
Any defective ATB1 should be returned to
Fieldpiece for warranty service along with proof of
purchase.
Fieldpiece Instruments, Inc.
580 West Central Avenue, Suite A
Brea, California 92821
(714) 257-9060 Fax: (714) 257-9069
WARNINGS
When testing hot tempera-
tures, the thermocouple and
velcro may become hot. Do
not handle the thermocouple
or the velcro when hot.
!
!
K-type Thermocouple
Model: ATB1
Max: 400ºF
OPERATOR’S MANUAL
Description
The ATB1, K-Type, thermocouple can be used
continously to take temperature readings up to
400ºF and a one time use of 482ºF. The ATB1 can
be used with any thermometer which accepts a K-
type thermocouple.
The velcro allows the user to strap the ATB1 to a
pipe, allowing the user to take hands free, more
accurate measurement. The ATB1 also comes with
a wrap tab making it easy to wind and store the
thermocouple.
Operation
To use the ATB1 plug it into any thermometer
accepting a K-type thermocouple and adjust the
device to the appropriate settings. To use velcro
strap, Insert the thermocouple through the velcro as
shown below and strap it to the pipe.
Calibration
Due to variances in the thermocouple wire and
other parts of the system, a field calibration should
be conducted before use. Field calibration typically
gives +/- 1ºF overall accuracy. The instructions for
this calibration should be in the operating manual
for the thermometer.
Specifications
Thermocouple Conductors: K-type Nickel
Chromium/Nickel Aluminum, 2300ºF maximum
(insulation limits max. see probe insulation).
Accuracy: -50ºF to 400ºF +/- 4ºF,
Range: -50ºF to 400ºF maximum continous oper-
ation. Single exposure use at 482°F.
Probe insulation: While calibration and atmos-
phere will affect maximum useful temperature in
applications, this insulation is designated to
withstand a maximum continuous use at 400°F
(240°C) and a single exposure use at 482°F
(250°C).
Plug: K-Type Thermocouple male mini plug.
Broken Wires:
Due to frequent bending, the K-type thermocou-
ple wire may break or come loose, typically near the
plug. To repair, cut and strip the thermocouple wire
near the plug. The red wire is the (-) wire and it
belongs on the wider of the two plugs. Loosen the
screws on plugs and wind the conductors around
the appropriate screws and tighten. Finally, position
the plugs into the tab and screw the tab back
together.
Warranty
The ATB1, K-Type, thermocouple is warranted
against manufacturer’s defects for one year. This
warranty does not apply to defects resulting from
abuse, neglect, accident, unauthorized repair, alter-
ation, or unreasonable use of the instrument. Any
implied warranty arising out of the sale of
Fieldpiece's products including but not limited to
implied warranties of merchantibility, and fitness for
purpose, are limited to the above. Fieldpiece shall
not be liable for incidental or consequential dam-
ages.
Service
Any defective ATB1 should be returned to
Fieldpiece for warranty service along with proof of
purchase.
Fieldpiece Instruments, Inc.
580 West Central Avenue, Suite A
Brea, California 92821
(714) 257-9060 Fax: (714) 257-9069
WARNINGS
When testing hot tempera-
tures, the thermocouple and
velcro may become hot. Do
not handle the thermocouple
or the velcro when hot.
!
!