6. TECHNICAL SPECIFICATIONS
FVC 2001-EK FVC 2003-EK
Voltage/Frequency 230 V
~
50 HZ 230 V
~
50 HZ
Power input 250 W 400 W
Maximum transferred amount 5000 l/h 7500 l/h
Maximum delivery 6 m 5 m
Maximum submersible depth 5 m 5 m
Maximum temperature of the media 35 °C 35 °C
Maximum value of solid particles in the media Dia. 5 mm Dia. 35 mm
Height of the switching point: On Approx. 50 cm Approx. 50 cm
Height of the switching point: Turned off Approx. 5 cm Approx. 5 cm
7. WHAT TO DO "WHEN..."
When... Causes Repairs
The pump does not start – No power supply
– The fl oat does not switch
– Check the power supply
– Move the fl oat to a higher position
Not fl owing – The suction sieve is clogged
– The pressure hose is bent
Flush out the suction sieve with
a current of water
– Straighten the hose
The pump does not
turn off
– The fl oat cannot fall lower Place the pump correctly
on the fl oor of the tank
Insuf cient fl ow – The suction sieve is clogged
Lowered pump capacity due to dirty
and silted water
Clean the suction sieve
Clean the pump and fl ush the hose
with clean water
The pump turns off
after a short time
The temperature fuse stops the
pump due to dirty water
The water is too hot. The temperature
fuse stops the pump
Disconnect the power plug.
Clean the pump and the pumping pit
Check that the maximum water
temperature of 35 °C is not exceeded
Note: Not covered by warranty:
Damage to the rotating mechanical gasket caused by running the pump empty, or by foreign objects
in the water
Blocking of the running wheel by foreign objects
Damage during transport
Damage caused by unprofessional alterations by persons