Specification
7
Control Kits
(Required to Operate SWG Power
Venters and Draft Inducers)
CK-61
All oil-fired systems. Has adjustable electronic post purge.
CK-62
All oil-fired systems. Has thermally activated post purge.
CK-63
All oil-fired systems. (May require optional delay oil valve for
simultaneous burner operation.)
CK-20FV
CK-20FG
30 millivolt gas-fired water heaters and gas-fired pool or
spa heaters with a manual or internally mounted thermostat.
CK-21
Gas-fired instantaneous water heaters with pressure tap port
in the burner manifold.
CK-41F
CK-41P**
Furnaces, boilers, unit heaters and water heaters operating with a
24 VAC gas valve without factory mounted spillage switches.
CK-43
Draft induced 24 VAC gas valve systems. Includes a 4' MG-1
draft control and post purge.
CK-43F
CK-81***
750 millivolt operated boilers, furnaces, water heaters, pool or spa
heaters and gas-fired fireplaces when operated with a remote mounted
thermostat or on/off switch. Operated off a 24 VAC circuit.
CK-91FV
CK-91FG
Gas-fired draft induced 24 VAC gas valve systems and a 30 millivolt
operated water heater. Includes a 4' MG-1 draft control and post purge.
CK-92FV
CK-92FG
CK-92FVP**
CK-92FGP**
Gas-fired furnace or boiler and a 30 millivolt operated water heater.
Includes post purge.
30 mv
Co-venting Multiple
Appliances
24 v750 mv
Draft Proving Switch
Gas Pressure Switch
Secondary Safety Switch
Thermal Post Purge
Adjustable Electronic
Post Purge
Fixed Post Purge
Draft Control
* Control Kits are ETL approved accessories when used in conjunction with the SWG Power Venter.
** Plugs into 24v electric damper
*** A secondary safety switch should be used with a CK-81
F = Fixed Post Purge FV= right hand threaded TCA Safety Switch FG= left hand threaded TCA Safety Switch
CK-41F mounted at venter. For use with a 24 VAC,
gas-fired system (shown with cover off).
CK-63 remote mounted. For use with 120 VAC oil-fired systems.
Electronic post purge is included (shown with cover off).
Control Kit Installation
RJR-6
Applications
Control Kit*
Control Kits (CK) control the operation of SWG Power
Venters. See the chart below to select the proper kit for
your application. Control Kits can also control the
operation of Field Draft Inducers.
CK kits can be mounted up to 100 feet from venter.
Oil
Gas