I. TYPICAL VENTING SYSTEM COMPONENTS:
1 - PVE Series Power Venter
1 - SWH-1 Series Sidewall Vent Hood (Not included)
1 - CK Series Control Kit (Not included)
A. DESCRIPTION OF POWER VENTER MODELS
Unit Dimensions (inches) ELECTRICAL DATA
MODEL
"H" "W" "D"
INLET/
OUTLET
VOLTS Hz RPM WATTS AMPS
THERMAL
PROT.
PVE-100 7.50 7.75 7.00 4.00 120 60 3000 145 2.1 YES
PVE-300 7.50 9.25 7.00 4.00 120 60 3000 145 2.1 YES
PVE-600 8.75 9.75 8.50 5.00 120 60 3000 167 1.5 YES
PVE-1200 13.75 12.50 13.50 8.00 120 60 1725 280 2.5 YES
B. SIDEWALL VENT HOODS (SWH-1):
Sidewall vent hoods are available in the following sizes. The vent hood should be chosen
that matches the outlet size of the Power Venter. Note: Different sizes may be used as long
as the reducers and specific size pipe are considered when determining equivalent length of
vent pipe.
SWH-1-3 - 3 inch
SWH-1-4 - 4 inch
SWH-1-5 - 5 inch
SWH-1-6 - 6 inch
SWH-1-8 - 8 inch