Brochure

Technical Service: 800.742.8368 fieldcontrols.com 15
FLUE DAMPERS
Automatic Flue Dampers
SIZING & SELECTION
FSE Series
Voltage Frequency Current Maximum Current Operating Temperature Timing
24 VAC 50/60 Hz 80 mA 5 A
Controller: -40˚-140˚F
Pipe: -40˚-650˚F
7 seconds to open
30-40 seconds to close (including time delay)
Model
Dimensions (Inches)
Weight (lbs.)
A B C D
FSE-6 5.9 6.0 14.5 11.8 6.0
FSE-8 7.8 10.5 17.0 13.8 7.8
FSE-10 9.8 10.5 19.0 15.8 8.9
FSE-11 10.8 10.5 20.0 16.8 9.4
FSE-12 11.8 10.5 21.0 17.8 10.0
FSE-13 12.8 12.5 22.0 18.8 11.3
FSE-14 13.8 12.5 23.0 19.8 12.0
FSE-16 15.8 12.5 25.0 21.8 13.3
FSE-18 17.8 13.5 27.0 23.8 15.6
FSE-20 19.8 14.5 29.0 25.8 17.8
FSE-22 21.8 15.5 31.0 27.8 20.1
FSE-24 23.8 16.5 33.0 29.8 22.9
FSM Series
Controller Voltage Switching Voltage Battery Life Operating Temperature Timing
3.6 VDC 100-750 mVDC 10 years
Controller: -40˚-140˚F
Pipe: -40˚-650˚F
7 seconds to open
30-40 seconds to close @ 450mV
Model
Dimensions (Inches)
Weight (lbs.)
A B C D
FSM-6 5.9 6.0 14.5 11.8 6.0
FSM-8 7.9 10.5 17.8 13.8 7.8
FSM-10 9.9 10.5 19.8 15.8 8.9
FSM-11 10.9 10.5 20.8 16.8 9.4
FSM-12 11.9 10.5 21.8 17.8 10.0
FSM-13 12.9 12.5 22.8 18.8 11.3
FSM-14 13.9 12.5 23.8 19.8 12.0
FSM-16 15.9 12.5 25.8 21.8 13.3
FSM-18 17.9 13.5 27.8 23.8 15.6
FSM-20 19.9 14.5 29.8 25.8 17.8
FSM-22 21.9 15.5 31.8 27.8 20.1
FSM-24 23.9 16.5 33.8 29.8 22.9
Model
Dimensions (Inches)
Weight (lbs.) Clearance (in.)
A B C D
FSE-L6/ FSM-L6 5.9 6.0 14.5 11.8 4.02 .25
FSE-L8/ FSM-L8 7.9 6.0 16.5 13.8 4.25 1.25
FSE-L10/ FSM-L10 9.9 6.0 18.5 15.8 5.25 2.25
FSE-L11/ FSM-L11 10.9 6.0 19.5 16.8 5.81 2.75
FSE-L12/ FSM-L12 11.9 6.0 21.5 17.8 6.36 3.25
FSE-L13/ FSM-L13 12.9 6.0 22.5 18.8 6.55 3.75
FSE-L14/ FSM-L14 13.9 6.0 23.5 19.8 7.07 4.25
FSE-L16/ FSM-L16 15.9 6.0 25.5 21.8 8.25 5.25
FSE-L18/ FSM-L18 17.9 6.0 27.5 23.8 9.80 6.25
FSE-L20/ FSM-L20 19.9 6.0 29.5 25.8 11.25 7.25
FSE-L22/ FSM-L22 21.9 6.0 31.5 27.8 12.35 8.25
FSE-L24/ FSM-L24 23.9 6.0 33.5 29.8 13.75 9.25
D
C
FSE Series
A
B
C
A
B
D
D
C
A
B
Low Profile
FSE Low Profile & FSM Low Profile - Vent Cap Required