Brochure
14 Customer Service: 252.522.3031
FLUE DAMPERS
Select the round or rectangular Flue Sentinel model that fits your opening.
For round dampers, determine whether you want a low profile or standard profile Flue Sentinel. The low profile
models require a chimney cap, a “dog house” or site built enclosure. Standard models do not require a chimney cap
but a “dog house” or site built enclosure is recommended.
Choose accessories:
• High Temperature Wire
• Combustion Air Unit or Fresh Air Damper for combustion air
• Electronic Ignition Kits are available to convert mV to 24v
• Chimney Cap
Automatic Flue Dampers
SIZING & SELECTION
ROUND OR RECTANGULAR
SIDE VIEW
TOP VIEW
ROUND FLUE TILE
TOP VIEW
RECTANGULAR TILE
FLUE TILE
BRICK
BRICK
ROUND
FLUE TILE
RECTANGULAR
FLUE TILE
** Special Order **
TOP VIEW SIDE VIEW
(Rectangular)
SITE BUILT
BRICK OR BLOCK
Determine if the gas log set is 24v or mV.
Determine the style of chimney the Flue Sentinel will attach to and measure the opening per the instructions below:
Class A Chimney Pipe -
Measure the inside diameter.
Vented or Air Pipe - If the pipe manufacturer is
known, select the appropriate Chimney Pipe Adapter Kit
(see accessories section). Otherwise, measure the inside
pipe diameter
and match
to the outer
adapter kit
diameter.
Clay/Flue Tile - If round, measure the inside
diameter. If rectangular, measure the length and
width of the opening.*
Site Built Chimney - If rectangular, measure the
length and width of the opening. Allow 4 weeks for
custom manufacturing.*
1
2
3
4
5
(Round Pipe)
AIR-COOLED
CHIMNEY
* Requires FSK Mounting Kit
AIR GAP
* FSK
MOUNTING KIT
METAL
OUTER
PIPE
METAL
INNER
PIPE
*Note: A round unit can be used in a rectangular or square opening with the appropriate adapter or ashing.