GRAVITY DAMPER INFORMATION
ELECTRICAL REQUIREMENTS
The Everest Series Whole-House Fan Systems require a 115 volt electrical power supply of minimum 15A am-
pacity and maximum 15 Amp circuit overcurrent protection. We strongly recommend providing a dedicated
circuit for this fan system.
All electrical components, whether included with the system or supplied by others, must be rated for the fan
systems electrical load requirements; please refer to the
Everest Series
speci cations table for the electrical
load requirements of the speci c model to be installed.
All wiring and connections must be made according to this manual and all applicable electrical
wiring codes and standards. All applicable electrical codes must be followed to the satisfaction of the local
authority having jurisdiction.
Everest Series Whole-House Fan Systems are shipped with a pre-wired 20 foot 115V power cord that
Everest Series Whole-House Fan Systems are shipped with a pre-wired 20 foot 115V power cord that
may be used to operate the fan by means of a switched or remote-controlled 115V grounded outlet mounted
may be used to operate the fan by means of a switched or remote-controlled 115V grounded outlet mounted
in the attic. A wall switch rated for the fan systems electrical load requirements may be mounted in
in the attic. A wall switch rated for the fan systems electrical load requirements may be mounted in
the living space and used for simple single-speed control of the fan. The power cord is pre-wired to operate
the living space and used for simple single-speed control of the fan. The power cord is pre-wired to operate
the fan on high speed only but may be re-wired for low speed operation if desired; please refer to the appro-
the fan on high speed only but may be re-wired for low speed operation if desired; please refer to the appro-
priate wiring diagrams for further information. If a remote-controlled outlet is used for fan control, the remote
priate wiring diagrams for further information. If a remote-controlled outlet is used for fan control, the remote
outlet must be rated for the electrical load requirements of the speci c model to be installed.
outlet must be rated for the electrical load requirements of the speci c model to be installed.
Everest Series Whole-House Fan Systems also include wall mount electrical control components including
Everest Series Whole-House Fan Systems also include wall mount electrical control components including
a multi-speed switch, a white Decora duplex wall plate, and plastic single gang wall box. These controls may be
a multi-speed switch, a white Decora duplex wall plate, and plastic single gang wall box. These controls may be
installed to provide multi-speed control of the fan from within the living space. Please refer to the appropriate
installed to provide multi-speed control of the fan from within the living space. Please refer to the appropriate
wiring diagrams for further information on the proper wiring con guration: either 2 speed hardwired or single
wiring diagrams for further information on the proper wiring con guration: either 2 speed hardwired or single
speed operation using pre-wired power cord.
speed operation using pre-wired power cord.
The
The
Everest Series
Everest Series
Whole House Fan Systems have di erent gravity damper sizes, depending on the speci c
Whole House Fan Systems have di erent gravity damper sizes, depending on the speci c
model to be installed. Verify which gravity damper size is provided with your system prior to beginning
model to be installed. Verify which gravity damper size is provided with your system prior to beginning
installation of the product.
installation of the product.
The Everest Series fan systems include gravity-closed gravity damper doors that are opened by air
pressure created by fan operation. The dampers serve to block entry of air from the attic into the living space, and
are provided with foam sealing and insulating material in the doors to reduce heat transfer from the attic space.
P/N 780105003 11/20 Rev A