WIRING INSTRUCTIONS
Wire the venter motor and controls in accordance with the National Electrical Code, manufacturer's
recommendations and/or applicable local codes. UNIT MUST BE GROUNDED. Check ground circuit to
make certain that the unit has been properly grounded. The wiring should be protected by an over current
circuit device rated at 15 amperes. Caution must be taken to ensure that the wiring does not come into
contact with any heat source. All line voltage and safety control circuits, between the venter and the
appliance, MUST be wired in accordance with the National Electrical Code for Class I wiring or equivalent
methods.
Route the venter motor and control wiring with an appropriate wiring method. (Diagrams A through F)
NOTE: Control is factory set for 120V wiring. For 24V wiring connect the yellow mode wire to the 24V terminal.
NOTE: Circuit board is polarity sensitive. Follow check-out procedures.
Diagram A – Oil Fired System: Single Unit Wiring
Figure 6
Close-Up of Interior Board Layout