Instructions / Assembly

Page 6
ADJUSTMENTS
PRESSURE SWITCH ADJUSTMENTS
With the venter air flow set and the appliance operating at the best
operating efficiency, adjust the pressure switch by rotating the
adjustment screw clockwise until the burner shuts off, then rotate the
adjustment screw counterclockwise until the burner fires. Rotate the
adjustment screw an additional 1/4 turn counterclockwise to ensure
proper switch setting. (See Figure 6)
P
OST PURGE TIMING ADJUSTMENT
To adjust the post purge time, refer to Figures 7 & 8.
For timer that looks like Figure 7: Rotate the timer adjustment on the
timer clockwise to increase the operation time. To decrease the
operation time, rotate the timer adjustment counterclockwise.
For timer that looks like Figure 8: Rotate the timer adjustment on the
timer counterclockwise to increase the operation time. To decrease the
operation time, rotate the timer adjustment clockwise.
*Typical post purge time should be between 3 to 5 min.
Figure 8
Figure 6
Figure 7