Instructions / Assembly

Page 3
WIRING INSTRUCTIONS
Wire the venter motor and
controls in accordance with
the National Electrical Code,
manufacturer's
recommendations and/or
applicable local codes. UNIT
MUST BE GROUNDED.
Check ground circuit to make
certain that the unit has been
properly grounded. The wiring
should be protected by an over
current circuit device rated at
15 amperes. Caution must be
taken to ensure that the wiring
does not come into contact
with any heat source. All line
voltage and safety control
circuits, between the venter
and the appliance, MUST be
wired in accordance with the
National Electrical Code for
Class I wiring or equivalent
methods. Route the venter motor
and control wiring with an
appropriate wiring method.
(Diagrams A through E)
Diagram AOil Fired System: Single Unit Wiring
Diagram BOil Fired System: Wiring with Electronic Primary