Cascade Series Install Manual
page 7 of 16
The ideal orientation of unit’s gravity damper is in a level position. If necessary, however, the damper can be in-
stalled at a slight angle. TIP: before beginning the installation, make sure that the fan assembly is undamaged, 
and that the fan blade rotates freely. Brace or clamp the fan assembly to a secure object, and temporarily plug 
in the fan’s power cord into a grounded power outlet to verify smooth and correct operation. 
 Be aware that the fan is quite powerful and will draw in loose objects or de
Be aware that the fan is quite powerful and will draw in loose objects or de
bris, and will blow dirt,  
bris, and will blow dirt, 
      debris and other objects with force!
     debris and other objects with force!
Use eye protection when operating the fan to avoid injury from blowing sand or debris! Keep hands 
Use eye protection when operating the fan to avoid injury from blowing sand or debris! Keep hands 
      and other objects away from the rotating fan blade!
     and other objects away from the rotating fan blade!
TIP: Before beginning the installation, verify that the damper assembly is undamaged, and that the damper   
    doors operate freely, opening and closing fully without binding or restriction.
INSTALLATION: GRAVITY DAMPER
GRAVITY DAMPER ORIENTATION NOTE
1.   From consideration of the principles of whole-house 
fan  operation, determine the best general area for 
installation of the gravity damper assembly. The 
damper assembly is to be mounted in the attic with 
its bottom edge opening into and   ush with the 
ceiling of the living space. The eggcrate inlet grille 
is to be mounted on the ceiling of the living space,
covering and engaging with the opening of the 
damper assembly.
2.   Using the cardboard from the fan system’s packaging,
or other suitable material, make a rectangular tem-
plate for the rough opening of the damper assembly 
to these dimensions making sure all sides are at right 
angles to each other):
 a. Cascade CA 6.5 model: 14-1/4” wide, 36-1/4” long
FIGURE 1 - TEMPLATE
3.    Take the template into the attic, above the general area for installation, and determine the exact desired 
    location for the rough opening for installation of the damper assembly. There must be at least 36” of
    vertical clearance above the damper assembly location, and the damper assembly must be fastened to 
    secure framing (ceiling joist, roof truss, or additional framing) along at least one long side or both short 
    sides of the damper assembly! Add additional framing as required to support the weight of the damper 
   assembly and duct.
    a.  For existing construction, the  anges surrounding the opening of the damper assembly may
      be removed for clearance (as with 16” on-center framing) and/or to allow the side or sides of 
      the damper assembly to make direct contact with the framing used to support the damper
  assembly.  Leave   anges in place if they will not be fastened to framing, if possible. Additional framing 
      may be added after the damper assembly is placed into the rough opening, so the  anges can 
      remain in place if space allows.
    b.  For new construction, before the ceiling drywall is hung, frame in a rough opening for
      installation of the damper assembly from below. Leave the assembly  anges in place and
      simply attach the damper assembly to the bottom of the framing using appropriate
      fasteners installed through the  anges. Skip all following steps regarding cutting the rough
      opening into the ceiling and proceed with installation of the duct and fan assembly.
P/N 780105002 01/21 Rev A