Cascade Series Install Manual
page 4 of 16
GRAVITY DAMPER INFORMATION
ELECTRICAL REQUIREMENTS
The 
Cascade
 Series Whole-House Fan Systems require a 115 volt electrical power supply of minimum 15A am-
pacity and maximum 15 Amp circuit overcurrent protection. We strongly recommend providing a dedicated 
circuit for this fan system.
All electrical components, whether included with the 
Cascade
 system or supplied by others, must be rated 
for the fan system’s electrical load requirements; please refer to the 
Cascade 
Series speci cations table for the 
electrical load requirements of the speci c model to be installed.
All wiring and connections must be made according to this manual and all applicable electrical 
wiring codes and standards. All applicable electrical codes must be followed to the satisfaction of the local 
authority having jurisdiction.
Cascade Series Whole-House Fan Systems are shipped with a pre-wired 20 foot 115V power cord that may be 
used to operate the fan by means of a switched or remote-controlled 115V grounded outlet mounted in the 
attic. A wall switch rate for the fan system’s electrical load requirements may be mounted in the living space 
and used for simple single-speed control of the fan. The power cord is pre-wired to operate the fan on high 
speed only but may be re-wired for low speed operation if desired; please refer to the appropriate wiring dia-
grams for further information. If a remote-controlled outlet is used for fan control, the remote outlet must be 
rated for the electrical load requirements of the speci c model to be installed. 
Cascade Series Whole-House Fan Systems include wall mount electrical control components including 2 multi-
speed switches, a white Decora duplex wall plate, and a plastic double gang wall box. These controls may be 
installed to provide multi-speed control of the fan from within the living space. Please refer to the appropriate 
wiring diagrams for further information on the proper wiring con guration.
The 
The 
Cascade
Cascade
  Series  Whole  House  Fan  Systems    have  di erent  gravity  damper  sizes,  depending  on  the
 Series Whole House Fan Systems have di erent gravity damper sizes, depending on the
speci c  model  to  be  installed.    Verify  which  gravity  damper  size  is  provided  with  your  system  prior  to
speci c model to be installed. Verify which gravity damper size is provided with your system prior to
beginning installation of the product.
beginning installation of the product.
The Cascade Series fan systems include gravity-closed gravity damper doors that are opened by air
pressure created by fan operation. The dampers serve to block entry of air from the attic into the living space, and 
are provided with foam sealing and insulating material in the doors to reduce heat transfer from the attic space.
P/N 780105002 01/21 Rev A