VI. TROUBLE SHOOTING HINTS
1. Venter does not activate when thermostat calls for heat.
a. Check wiring.
b. Check gas pressure switch for continuity across terminals when gas valve is pressurized.
c. Check gas pressure.
2. Flue gas odor:
a. Check system draft.
b. Check for negative pressure in building.
3. Pilot will not stay lit on water heater:
a. Solder all spillage switch wire terminal connections.
b. Check reset buttons on spillage switches.
c. Use 12 gage wire for all spillage switch wiring.
d. Check for interruption of supply power.
VII. REPAIR AND REPLACEMENT PARTS LIST
REPAIR AND REPLACEMENT PARTS LIST
DESCRIPTION PART NUMBER
Gas Pressure Switch 46284200
GSK-3 Spillage Switch 46086400
TCA-1 46082700
TCA-2 (Flameguard Only) 46429900
DI-1 46073000
DI-2 46075300
DI-3 46090700