User Guide
Software Functional Overview
3-22 FIC MD02 Service Manual
Regist
er
Bit Number
Functio
n
Address
Name
R/W
7
6
5
4
3
2
1
0
Logic
Default
Description
*3
2
nd
Battery
[ _BST
]
3Eh
to
44h
*3
*2 *2 *2 *2
*2 *2
2
nd
Battery
[ _BTP
]
46h *2 *2 *2 *2
*2 *2
-
48h
Battery
data
Size
R
(/W)
DATA [7:0] - -
0x01: DATA size is
3byte.(PMU06A)
0x00: DATA size is 2 byte.
(PMU06) *8
49h
Design
capacit
y
R
(/W)
DATA [23:16] *1 *7
- 0xff
PMU06A use this data
with 02/03h. *7 *8
1
st
Battery
[_BIF]
4Ah
Last
Full
Charge
Capaci
ty
R
(/W)
DATA [23:16] *1 *7
- 0xff
PMU06A use this data
with 04/05h. *7 *8
1
st
Battery
[_BST]
4Bh
Battery
Remai
ning
Capaci
ty
R
(/W)
DATA [23:16] *1 *7
- 0xff
PMU06A use this data
with 1E/1Fh. *7 *8
1
st
Battery
[_BTP]
4Ch
Battery
Trip
Point
R
(/W)
DATA [23:16] *1 *7
- 0x00
PMU06A use this data
with 22/23h. *7 *8
4Dh
Design
capacit
y
R
(/W)
DATA [23:16] *1 *7
- 0xff
PMU06A use this data
with 26/27h. *7 *8
2
nd
Battery
[_BIF]
4Eh
Last
Full
Charge
Capaci
ty
R/(/W
)
DATA [23:16] *1 *7
- 0xff
PMU06A use this data
with 28/29h. *7 *8
2
nd
Battery
[_BST]
4Fh
Battery
Remai
ng
Capaci
ty
R
(/W)
DATA [23:16] *1 *7
- 0xff
PMU06A use this data
with 42/43h. *7 *8
2
nd
Battery
[_BTP]
50h
Batt
ery
Trip
Point
R
(/W)
DATA [23:16] *1 *7
0x00
PMU06A use this data
with 46/47h. *7 *8
PDF created with FinePrint pdfFactory trial version http://www.fineprint.com