User Guide

Software Functional Overview
FIC MB02 Service Manual 3-29
Register Bit Number
Function
Addre
ss
Name
R/W
7
6
5
4
3
2
1
0
Logic Default
Description
C3h
EC_RUN_
ENB_2
R/W
0: Disable
1: Enable
0x00
C4h
EC_WAKE_
ENB_2
R/W
Reserved [7:1]
T
H
0: Disable
1: Enable
0x00
TH: Thermal event
C5h
To
C7h
Reserved R/W
Dont care
- -
C8h
*6
GPI_AD0 R AD0_DATA [7:0] - -
C9h
*6
GPI_AD1 R AD1_DATA [7:0] - -
For detail in
formation, refer
to GPIO section in this
document.
CAh
*6
Reserved
R/W Dont care - -
CBh
D/A_CONT
R/W DATA [7:0] - 0xff
0x00-0xfe: D/A converter
output data
0xff : Battery
capacity(%) output
D0h
BAT_CHG_
CONT
R/W RES[7:5]
C
H
G
_
R
D
Y
#
RES
[3:2]
C
H
G
2
C
H
G
1
- -
CHG_RDY# =0 : Charge
ready
CHGn =1 : The nth
battery is charged
D1h
BAT_DCH_
PRI
R/W RES[7:3]
PAT
[2:0]
- 0x00
Battery discharge priority
0 : 2 1
1 : 1 2
2 : 2 1
3 : 2 1
4 : 1 2
5 : 1 2
6 : Same as 0
7 : Simultaneously
discharge (Read only :
This data can be set
using PMU register)
D2h
BAT_DCH_
CONT
R/W
RES[7:2]
D
C
H
G
2
D
C
H
G
1
0: Not discharge
1: Discharge
-
The discharge battery can
be selected one of the
batteries can be discharged.
D3h
BAT_WAR_
ABS
R/W DATA[15:0] *1 - 0x0000
Absolute capacity battery
Warning detection point
0x0000-0xffff (mWh)
D5h
BAT_LOW_
ABS
R/W DATA[15:0] *1 - 0x0000
Absolute capacity battery
Low detection point
0x0000-0xffff (mWh)
Battery
control
D7h
BAT_WAR_
REL
R/W DATA [7:0] - 0x10
Relative capacity battery
Warning detection point
00-C8h (0-100% step 0.5%)
PDF created with FinePrint pdfFactory trial version http://www.fineprint.com