User Guide

Software Functional Overview
3-22 FIC MB02 Service Manual
Register
Bit Number
Function
Address
Name
R/W
7
6
5
4
3
2
1
0
Logic
Default
Description
18h
*3
OEM
Informati
on
R(/W)
DATA
[15:8]
*1
All bits
are 0
Vender [7:0]
- 0xffff
Vender [7:0] This code depends on
battery data format.
And the following name should be
described in the ASL with the same
character code.
In the future, these codes will be
added.
0: MoliEnergy
1: Panasonic
2: “” (SANYO does not
agree the vender
name display)
3: TBCL (Toshiba)
4: Sony
Register
Bit Number
Function
Address
Name
R/W
7
6
5
4
3
2
1
0
Logic
Default
Description
1Ah
*3
Battery
State
R (/W)
DATA[15:3] *1
All bits are 0
C
R
I
T
C
H
G
D
C
H
G
- -
DCHG=1:
CHG =1:
CRIT =1:
The battery is
discharged
The battery is
charged
The battery is
critical (Empty)
1Ch
*3
Battery
Present
rate
R (/W)
DATA[15:0] *1 - 0xffff
0x0000-0xfffe(mW)
0xffff: Unknown
1Eh
*3
Battery
Remainin
g
Capacity
R (/W)
DATA[15:0] *1 - 0xffff
0x0000-0xfffe(mWh)
0xffff: Unknown
1
st
Battery
[ _BST ]
20h
*3
Battery
present
Voltage
R (/W)
DATA[15:0] *1 - 0xffff
0x0000-0xfffe(mV)
0xffff: Unknown
1
st
Battery
[ _BTP ]
22h
Battery
Trip Point
R/W DATA[15:0] *1 - 0x0000
0x0000: Clear the trip point
0x0001-0xffff(mWh)
2
nd
Battery
[ _BIF ]
24h
to
3Ch
*3
*2 *2 *2 *2 *2 *2
2
nd
Battery
[ _BST ]
3Eh
to
44h
*3
*2 *2 *2 *2 *2 *2
2
nd
Battery
[ _BTP ]
46h *2 *2 *2 *2 *2 *2
-
48h
Battery
data
Size
R (/W)
DATA [7:0] - -
0x01: DATA size is
3byte.(PMU06A)
0x00: DATA size is 2 byte.
(PMU06) *8
49h
Design
capacity
R (/W)
DATA [23:16] *1 *7 - 0xff
PMU06A use this data with 02/03h.
*7 *8
1
st
Battery
[_BIF]
4Ah
Last Full
Charge
Capacity
R (/W)
DATA [23:16] *1 *7 - 0xff
PMU06A use this data with 04/05h.
*7 *8
PDF created with FinePrint pdfFactory trial version http://www.fineprint.com