Registe
r
Bit Number
Func
tion
A
dd
re
ss
Name
R/
W
7
6
54
3
21
0
Logic
Def
aul
t
Description
D
8h
BAT_
LOW_
REL
R/
W
DATA [7:0] -
0x0
6
Relative capacity battery
Low detection point
00-C8h (0-100% step
0.5%)
D
9h
*3
FULL_
DATA
R/
W
DATA [7:0] -
0x
be
Full charge cancel point
00-C8h (0-100% step
0.5%)
D
ah
CC_C
UR_
DATA
R
DATA [7:0] -
0x0
0
Battery charging current
setting
0x01-0xff (0.02-5.10A step
0.02A)
0x00 Depends on
the battery
This register is “read
only”, to change the
value, use the register in
PMU registers area.
D
B
h
To
D
C
h
BTP2
R/
W
DATA [15:0]
-
0x0
000
0x0000: Clear the trip
point
0x0001-0xffff : (mWh)
When all of the battery’s
capacities lesser than this
setting value, the BTP2 is
detected if event is
enabled.