8 Reliability
8.1 Limiting Voltage Range
The limiting voltage range is maximum voltage range that power supply and digital or analog input/output
interfaces can withstand.
8.1.1 Absolute Voltage Range
The absolute voltage range of MC116-NA series module is shown as table 8-1.
Table 8-1 Absolute voltage range
Parameter Description Min Typ Max Unit
VBAT Power supply -0.3 3.8 4.7 V
GPIO Digital IO supply voltage -0.3 1.8 2.0 V
8.1.2 Operating Voltage Range
V
L
:logic low level; V
H
: logic high level.
Parameter
V
L
V
H
Unit
Min Max Min Max
Digital input -0.3 0.6 1.2 2.0 V
Digital output - 0.45 1.35 - V
Table 8-2 Operating Voltage Range
Parameter I/O Min Typ Max Unit
VBAT PI 3.3 3.8 4.3 V
USIM_VDD PO 1.7/2.75 1.8/2.85 1.9/2.95 V
8.2 Environment Temperature Range
The recommended operating temperature range of MC116-NA series module.is -30℃~+75℃. When
module operating at limited temperature range, some RF indexes may exceed standard, so module
application terminal should consider temperature control measurement. The module application terminal
is recommended storage in certain temperature conditions. Modules out of the temperature range may
not operate or may be damaged.
Table 8-3 Environment temperature range