User's Manual
Table Of Contents
- Preface
- Introduction
- Mechanical
- HardwareOverview
- HardwareInterface
- ElectricalandEnvironmental
- RFInterface
H380 M.2 Series Module Hardware User Manual page
33
of
41
23
WOWWAN# O
Module wake up the Host signal ,1.8V signal,
Input low level when wake up Host signal.
5.11 BODY_SAR Interface
H380 M.2 support BODY_SAR function.
BODY_SAR is an input signal (comes from AP output), high default, low active. AP can detect the
closing human body and output BODY_SAR low through proximity sensor. Module will reduce RF
transmitting power by BODY_SAR interrupt.
The threshold transmitting power can be configured by AT command.
No Name Type Description
25 DPR I BODY_SAR detection
5.12 Clock Interface
H380 M.2 support a 26MHz clock output, a 32KHz clock output.
No Name Type Description
46 SYSCLK O
26MHz clock output(for GPS device, as audio codec
MCLK)
68 CLK32K O 32KHz clock output
5.13 Config
H380 M.2 provides 4 configuration pins, the module is configured as WWAN-SSIC 0.
No Name Type Description Value
1 CONFIG_3 O Connected to Ground internally 0
21 CONFIG_0 O NC -
69 CONFIG_1 O Connected to Ground internally 0
75 CONFIG_2 O Connected to Ground internally 0
H380 M.2 Socket 2 Module type configuration as follows:
Config_0
(pin21)
Config_1
(pin69)
Config_2
(pin75)
Config_3
(pin1)
Module Type and Main
Host Interface
Port
Configuration
GND GND GND GND SSD-SATA N/A
GND GND N/C GND WWAN-PCIe N/A
N/C GND GND GND WWAN-SSIC 0