Installation Guide
Control Panel Instructions (pg 2)
Pair
Pairs a new wireless remote control.
To pair a new wireless remote (the included remote is already paired at the factory):
• Press and hold the pair button on the transformer. At the same time press and hold the M button on the new
remote. The LCD display will show rt to indicate that it is in remote pairing mode.
• Continue holding both buttons in for 8 to 10 seconds. When the new remote is paired, the output lights will
flash or flicker. The transformer will cycle through the dierent modes until both buttons are released.
Set Photocell
Sets the trigger point for turning the lights on and o.
To set the photocell level:
• Ensure mode is set to1h, 2h, 3h, 4h, 5h, 6h, 7h, 8h, or dd. The set photocell button will only work
when in these modes.
• Wait until the ambient outdoor light condition is at the desired level for when the lights are to come on (dusk).
• Press and continue to hold the Set Photocell button for 10 to 15 seconds. The LCD display will change to P5.
• The lights will flash or flicker once the new photocell setting has been saved.
• The set photocell button can be released. The LCD display will return to the previous setting.
• The lights will turn on in 30 to 40 seconds as long as the ambient light condition is lower than when it was set.
Remote Control
Controls the transformer remotely. Functions are the same as the transformer buttons.
• ▲ - Brightens the lights if they are on.
• ▼ - Dims the lights if they are on.
• - Turns the system power o and on.
• M - Changes the transformer mode.
• Pressing both ▼ and M in at the same time will put the transformer into Bluetooth pairing mode (see above).
The LCD display will show bt and no other functions will work for 30 seconds or until a new device is paired.
Additional Features
System Memory
• Previous settings are saved if power is lost. Settings are saved 30 seconds aer the last settings change.
• Saved settings include: system power (on or o), transformer mode, photocell trigger point, dimming level and wireless remote
codes (up to three dierent remotes can be paired at one time).
Overload Protection
• The transformer can sense an overload condition. When this occurs, the lights will shut o and the LCD display will show oL. This
can be caused by having too many lights attached or a pinched wire causing a short circuit.
• Pressing the power button twice will return the transformer to the previous mode. The system will then continue to check for an
overload condition every 10 seconds.
Over Temperature Protection
• The transformer can sense an unsafe internal temperature condition. When this occurs, the lights will shut o and the LCD display
will show ot. This can be caused by having the transformer too close to an external heat source.
• The transformer will automatically restart once the temperature has returned to a safe level. The system will continue to check for
an over temperature condition every 10 seconds.
Factory Reset
• Unplug the transformer for at least 10 seconds. Holding the power button in while plugging in the transformer will force the
transformer to return to factory settings. The power button can be released once the transformer turns on (the LCD display will
show Ao since this is the default mode). All settings will return to factory default. Any Bluetooth devices or replacement remote
controls will need to be paired again. The original remote control will not need to be paired again.