User's Manual
XGS-PON FGW User Manual
49
Setup
Q_PPS_DM_018_V1.3
Figure 17: Network provider connection
• Clean the optical connectors of the optical pactchcord, Figure 17, b), of the FiberGateway PON
port, Figure 17, a), and the optical wall socket , Figure 17, before connecting using appropriate
optical connector cleaning material;
• Plug one of the patchcord cleaned SC/APC optical connectors on the Fiber Gateway PON port,
Figure 17, a), observing the alignment mechanism, ( the tooth in the conector must fit into the
groove in the PON port connector: a click indicates the connector is secure into place)
• Plug the other end optical patchcord SC/APC connector on the optical wall socket observing
the alignment mechanism, ( the tooth in the conector must fit into the groove in the optical
wall socket connector: a click indicates the connector is secure into place)
• Accommodate the patchcord excessive length avoiding small bend radius on the patchcord
(30mm minimum bend radius).
4.11.2 Mains connection and power up
• Connect the power adaptor output connector to the 12-VDC power port on the equipment;
• Plug the power adaptor appropriate power cord into an approved 120VAC outlet, Figure 16;
• Switch on the equipment, ON-OFF button
After executing a power-up sequence the equipment will be ready for operation.