User's Manual
XGS-PON FGW User Manual
45
Setup
Q_PPS_DM_018_V1.3
Table 11: Connection cables
Connection
Description
C1
RJ11 Telephone cable
C2
Ethernet Cable UTP CAT56 cable (direct or crossover)
C3
Single-mode Optical Cable with SC/APC Connector (PON)
C4
12V DC Adapter
4.7 Before installing the Fiber Gateway equipment
4.7.1 Safety Warnings
• Fiber Gateway is a passive cooling device. To prevent equipment overheating do not obstruct
the ventilation grids on of the equipment;
• To avoid eye hazard, never look directly into a fiber optic port or connector;
4.7.2 Enviromental conditions
• Check for site’s temperature and humidity environmental conditions that must be within the
operating limits in the table bellow.
Operation Temperature (ºC)
+5 to +40
Operation Relative Humidity (%)
5 to 85
• Do not install the device in environments where the temperature or humidity exceeds the defined
limits!
• The ONT Gateway device is not designed for outdoor setup. Please place it in a convenient
indoor/cabinet environment;
4.7.3 Powering
• Install the device near a power outlet (110VAC) and the optical access point;
• Use only the provided power kit. The use of a third party power adapter may not guarantee its
proper operation;
4.7.4 Wireless network installation best practices
In order to achieve Fiber Gateway wireless network best performance the following installation rules
should be observed:
• Fiber Gateway front side should be oriented towards the area where the wireless network is to
be used;