User Manual
Table Of Contents
8
DIAGRAMS AND CONNECTION
TAMP
NC
SENS 1
SENS 2
Extending Flood Sensor contacts with a wired probe:
AUX COM Z1 Z2
EXTERNAL
SYSTEM HUB
ALARM
NC
TA MP
NC
SENS 1
SENS 2
+ 12
GND
TMP
Connection with external wired system:
NOTE
Mounting screws 
shown in a diagram 
are not included in 
the package. Choose 
a screw type depend-
ing on the building 
material it is being at-
tached to. 
i
CAUTION
Contacts SENS1 and 
SENS2 are dedicat-
ed to ood detection 
only. Do not connect 
external voltage!
!
NOTE
ALARM NC and TAMP 
NC connectors may 
be used as end-of-line 
protective loop’s ter-
minals.
i
NOTE
The Sensor detects 
electrical conductivity 
between electrodes 
1 and 3, 1 and 2 and 
electrodes connect-
ed to contacts (SENS1 
and SENS2). 
i
If you want the device to be mounted on a wall or in a distance from 
ooding source, sensor should be extended using an external probe 
(not included).
We recommend using extension probes or cables designed to detect 
water. Probes ends should be coated with non-corrosive metal. 
Connection wires should not be longer than 3m with 18-26AWG  
(0.14 - 0.82mm
2
). It applies also to VDC power source wires.