DIAGRAMS AND CONNECTION
Connecting the FIBARO Flood Sensor in a manner
inconsistent with manual may cause risk to health, life or
material damage.
!
Notes for the diagrams and probes marking:
+12V - 12 / 24 VDC positive terminal
GND - negative (ground) terminal
ALARM NC - potential-free ood sensor terminals (for wired systems)
TAMP NC - potential-free tamper terminals (for wired systems)
SENS1, SENS2 - ood sensor electrodes’ terminals
TMP - tamper button (used to add/remove the device)
ALARM
NC
TA MP
NC
SENS 1
SENS 2
+ 12
GND
TMP
#4: Diagrams and connection
1 2
3
12/24 VDC
ADAPTER
ALARM
NC
TA MP
NC
SENS 1
SENS 2
+ 12
GND
+
-
TMP
Connection to a constant power source:
NOTE
The TMP button has
two functions:
1. Adding / Removing
the device to / from
the Z-Wave network,
2. Tamper contact
for 4th Association
Group. When a sen-
sor is added to the
Z-Wave network, cov-
er open alarm may be
activated (according
to parameter 74 set-
tings).
i
CAUTION
Connect while observ-
ing wiring diagram
shown in this manual
only. Incorrect wiring
may be dangerous or
result in the device
breakdown.
Remember to keep
the device away from
water or protect holes
for wires from water to
avoid destroying the
device.
!
CAUTION
To prevent accidental
pulling out make cer-
tain that cables are
rmly attached to the
wire connectors and
screws are properly
tightened.
Make sure to secure
the power cord after
connecting it to the
terminal.
!